Stanley MB10 User Manual page 14

Mounted hydraulic breaker
Table of Contents

Advertisement

UNDERWATER USAGE
Underwater usage of the breaker will cause damage
to internal components. Even if the breaker is partially
submerged, water is introduced to an area between the
tool bit and piston. On the piston down cycle, the water
becomes compressed and damages adjacent compo-
nents.
DO NOT USE UNDERWATER
Do not use underwater without supplying air to breaker.
No part of the breaker may be submerged in water.
Underwater usage of the breaker will cause internal
damage to the breaker. Consult STANLEY for
modifications and specific warranty coverage if you
have an underwater requirement.
14 ► MB10 User Manual
OPERATION
GREASE THE BIT
Grease should be applied to the upper end of the break-
er tool bit each time it is installed. Thereafter, the tool
should be greased at the fitting to reduce wear in the
lower body and bushings of the tool. See Greasing The
Tool Bit in the sections titled Pre-Operation Procedures.

Advertisement

Table of Contents
loading

Table of Contents