Panasonic NN-T793SF APH Service Manual page 10

Hide thumbs Also See for NN-T793SF APH:
Table of Contents

Advertisement

RATED OUTPUT
1200W(IEC705-88)
1300W(IEC705-88)
1400W(IEC705-88)
4. PROCEDURE FOR MEASURING MICROWAVE
ENERGY LEAKAGE
NOTE:
The U.S. Government standard is 5 mW/cm
home. 2mW/cm
cm
for Canada)
2
4.1. Equipment
- Electromagnatic radiation monitor
- Glass thermometer 212°F or 100°C
- 600cc glass beaker
4.2. Procedure for measuring radiation leakage
Note before measuring.
- Do not exceed meter full scale deflection. Leakage monitor should
initially be set to the highest scale.
- To prevent false readings the test probe should be held by the grip
portion of the handle only and moved along the shaded area in
Figure no faster than 1 inch/sec (2.5cm/sec).
- Leakage with the outer panel removed ...... less than 5mW/cm
- Leakage for a fully assembled oven with door normally closed ......
less than 2mW/cm
- Leakage for a fully assembled oven [Before the latch switch
(primary) is interrupted] while pulling the door ...... less than 2mW/
cm
.
2
1. Pour 275 ± 15cc (9ozs
beaker which is graduated to 600cc, and place in the center of the
oven.
TEMPERATURE RISE
Min. 18.5°F(10.3°C)
Min. 19.8°F(11.1°C)
Min. 21.6°F(12.0°C)
stated here is our own voluntary standard. (1mW/
2
(1mW/cm
2
± 1/2oz) of 20°C ± 5°C (68° ± 9°F) water in a
s
while in the customer's
2
for Canada).
2
10
.