Carrier PIC 5+ User Manual page 56

Control for 19 series centrifugal chiller
Table of Contents

Advertisement

Table Name
PIC Table Type
PRESSURE
Menu Name
Status
EVAP_P
1
2
COND_P
3
ECON_P
4
OILP_DIS
5
OILP_SMP
6
OIL_PD
7
pd_off
-5.0 to 5.0
8
DIFF_P
9
HEAD_P
BRGI_P
10
11
BRGO_P
12
REF_PD
13
PUMPO_P
14
PUMPI_P
15
PUMP_PD
Table Name
PIC Table Type
INPUTS
Menu Name
Status
1
STAR_AUX
open/close
2
RUN_AUX
open/close
3
DMP_FC
no/yes
4
DMP_FO
no/yes
5
DMP_ACT
6
7
HGBP_FC
no/yes
8
HGBP_FO
no/yes
9
HGBP_ACT
10
11
HP_SW
open/close
12
REM_CON
open/close
13
E_STOP
open/close
14
ICE_CON
open/close
15
REM_LOCK
open/close
16
SAFETY
open/close
17
STARTFLT
open/close
18
FS_LOCK
open/close
19
GV1_OHMS
20
GV1_ACT
21
VFD_ACT
22
DIFF_ACT
23
AUTO_DEM
24
AUTO_RES
25
REF_LEAK
26
VFD_IN
27
GV1_MA
28
VFDC_MA
29
HGBPACTP
30
HGBP_MA
31
TRIPR
open/close
bacdongl
no/yes
32
33
SHAFTDIS
open/close
34
POW_FDB
open/close
35
FC_SS
open/close
36
CUS_ALE
open/close
37
FC_SS
off/on
38
CUS_ALE
Open/close
39
PGLE_LO
Open/close
40
PGLE_HI
Open/close
41
HF_LS
Open/close
56
Instance
HMI Menu Path
11H
3
//MAINMENU/
Default
Unit
Note Menu text description
PSIG
PSIG
PSIG
PSIG
PSIG
PSI
0
PSI
PSIG
PSI
PSIG
PSIG
PSI
PSIG
PSIG
PSI
Instance
HMI Menu Path
11H
4
//MAINMENU/
Default
Unit
Note Menu text description
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
%
%
%
mA
mA
mA
Volts
mA
mA
%
mA
-
-
-
-
-
-
-
-
-
-
-
Evaporator Pressure
Condenser Pressure
Economizer Pressure
Oil Supply Pressure
Oil Sump Pressure
Oil Pump Delta P
Oil/Ref Delta P Offset
Diffuser Pressure
Head Pressure Reference
Bearing Inlet Pressure
Bearing Outlet Pressure
Bearing Delta P
Pump Outlet Pressure
Pump Inlet Pressure
Ref Pump Delta P
Compressor Start Contact
Compressor Run Contact
Damper Valve Full Closed
Damper Valve Full Opened
Damper Valve Status
Cl=0,Inter=1,Op=2,Fail=3
EC Valve Fully Closed
EC Valve Fully Opened
EC Valve Status
Cl=0,Inter=1,Op=2,Fail=3
High Pressure Switch
Remote Contact
Emergency Stop Contact
Ice Build Contact
Chiller Lockout
Spare Safety Input
Starter Fault Feedback
Fire Security Interlock
Guide Vane 1 Actual Ohms
Guide Vane 1 Actual Pos
Actual VFD Speed Per
Diffuser Actual Pos
Auto Demand Limit Input
Auto Water Temp Reset
Refrig Leakage Sensor
VFD Speed Feedback
GV1 Pos Feedback
VFD Current Input
Actual ECV Pos Per
ECV Current Feedback
ISM Trip Relay Status
BACnet Dongle
Displacement Switch
Power Request Feedback
Free Cool Start Switch
Customer Alert
Free Cool Start Switch
Customer Alert
Purge Level Switch Low
Purge Level Switch High
Liquid Level Switch
Low
High
CCN
LEN
Limit
Limit
Force
Force
-5
5
x
Low
High
CCN
LEN
Limit
Limit
Force
Force