Troubleshooting - Broan HRV160 ECM User Manual

Hide thumbs Also See for HRV160 ECM:
Table of Contents

Advertisement

4. T
ROUBLESHOOTING
If the unit does not work properly, reset the unit by unplugging it for one minute and
then replug it. If it still not working properly, refer to table below. First make sure that
the integrated control is set to OFF (no LED lit).
PROBLEMS
1.
Nothing works.
2.
Condensation on windows
(air too humid).
3.
Inside air too dry.
4.
Air too cold at the air supply
grille.
5.
The LED of the integrated control
is blinking RED.
6.
The LED of the integrated control
is blinking GREEN.
7.
The LED of the integrated control
is blinking AMBER.
8.
The integrated control push
button does not work.
For wall controls problems, refer to the Troubleshooting section in the Main and auxiliary wall
controls user guide (included with the ventilation unit and also available at www.broan.com).
If the problem is still not solved, call your installer or the nearest approved Service Center.
Also, you can reach the Customer Service Department at the following phone number:
TRY THIS
• See if the unit is plugged in.
• See if the unit is receiving power from the
house circuit breaker or fuse.
• Operate the unit on maximum speed ventilation
until the situation is corrected.
• Leave curtains half-open to allow air circulation.
• Store all firewood in a closed room with a
dehumidifier or in a well ventilated room, or store
the wood outdoors.
• Do not adjust the thermostat of your heating
system below 64°F.
• Temporarily use a humidifier.
• Operate the unit in recirculation mode (if available).
• Check if the exterior hood is not blocked.
• Operate the unit in low speed ventilation, in
intermittent
available).
• Install a duct heater.
a) HRV160 ECM and ERV140 ECM only:
There is a problem with one of the motors.
The unit is OFF. Contact your installer.
b) HRV160: There is a problem with the exhaust
motor. The unit is OFF. Contact your installer.
• There is a problem with the thermistor. The
unit is still working, but will defrost frequently.
Contact your installer.
• There is a problem with the motorized damper.
The unit is OFF. For a 2½-hour period, the unit
will try to reset the damper at every 30 minutes.
After 2½ hours, if the problem is not solved, the
unit stops trying to reset damper.
Contact your installer.
• The 30-second boot sequence is not
completed. See point 2.1 on page 4.
1-877-862-7626.
8
or
in
recirculation
mode
(if

Advertisement

Table of Contents
loading

This manual is also suitable for:

Erv140 ecmHrv160