Split through-ceiling cooling system

Advertisement

Quick Links

Split Through-Ceiling Cooling System
Operation Care Installation Manual
WM-2500SSO WM-2500SSO-LA
WM-4500SSO WM-4500SSO-LA
R
e
a
d
R
e
a
d
Vinotemp International Corp
732 South Racetrack Road, Henderson, NV 89015
Tel: (800) 777-VINO Fax: (310) 886-3310 Email: info@vinotemp.com
w
w
w
.
v
i
n
o
t
e
m
w
w
w
.
v
i
n
o
t
e
m
a
n
d
s
a
v
e
t
h
e
a
n
d
s
a
v
e
t
h
e
p
.
c
o
m
p
.
c
o
m
s
e
i
n
s
t
r
u
c
t
i
o
n
s
e
i
n
s
t
r
u
c
t
i
o
n
s
s

Advertisement

loading

Summary of Contents for Vinotemp WINE-MATE WM-2500SSO

  • Page 1 Split Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSO WM-2500SSO-LA WM-4500SSO WM-4500SSO-LA Vinotemp International Corp 732 South Racetrack Road, Henderson, NV 89015 Tel: (800) 777-VINO Fax: (310) 886-3310 Email: info@vinotemp.com...
  • Page 2 Important Safety Information - 1 -...
  • Page 3: Table Of Contents

    Table of Contents Cellar Construction Guide------------------------------------------3 Features & Specifications------------------------------------------4 Temperature & Humidity--------------------------------------------6 Care Guide-------------------------------------------------------------10 User’ Troubleshooting---------------------------------------------11 Installer’s Instructions---------------------------------------------14 Electrical Wirings----------------------------------------------------25 Warranty----------------------------------------------------------------27 - 2 -...
  • Page 4: Cellar Construction Guide

    Cellar Construction Guide This is only a guide and shall be considered as the minimum requirements. All interior walls, ceilings and floors shall have a vapor barrier and a minimum of R13 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
  • Page 5: Features & Specifications

    Features and Specifications  WINE~MATE split through-ceiling cooling systems WM-2500~4500SSO and WM-2500~4500SSO-LA are designed to provide a cold environment between 50~65 °F with a humidity range within 50~70% RH for a properly insulated wine cellar.  These temperature and humidity ranges are optimized for long term storage of wine like that in natural caves.
  • Page 6 If the condensing unit will operate below 50°F, install a low CAUTION ambient condition kit. The cooling capacity is determined under 55°F cellar temperature, 75°F cellar ambient temperature and 90°F condensing unit ambient temperature, with R13 interior and NOTE R19 exterior insulations. Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55°F.
  • Page 7: Temperature & Humidity

    Temperature and Humidity 1. The controller Fig. 2 TEMPERATURE CONTROLLER 1) Keys SET: To display set-point; in programming mode it selects a parameter or confirms an operation. : To start a manual defrost. : To see the maximum stored temperature; in programming mode it browses the parameter codes or increases the displayed value.
  • Page 8 4) Alarm Signals The alarm codes are described as follows. MESSAGE CAUSE FUNCTION Temperature probe faulty Compressor switching to Con and CoF Probe temperature ALU higher than the High temperature alarm setting temperature; Outputs unchanged Probe temperature ALL lower than the Low temperature alarm setting temperature;...
  • Page 9 5. Manual Defrost Press and hold the defrost key until defrost starts. The defrost indicator will be 6. Parameter Programming 1) Press and hold the SET + keys until the “°C” or “°F” LED starts flashing, then release the keys. 2) Press and hold again the SET + keys until the Pr2 label is displayed, then release the keys.
  • Page 10 7. How to calibrate the air probe If the actual cellar temperature differs from the setting temperature, set parameter ot = actual cellar temperature minus set-point. 8. How to adjust defrost settings In case there is excessive frost, the parameters FnC = C-y, idF = 4 and MdF = 20 can be used to avoid frost.
  • Page 11: Care Guide

    Care Guide In general, always unplug system or disconnect power while doing care. 1. Condenser Coil Cleaning  Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months.  Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty.
  • Page 12: User' Troubleshooting

    User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive. Complaint Possible Causes Response 1. Unit not running a. Power cord not plugged a. Check power cord b.
  • Page 13 minimum 1 foot clearance for the ambient air intake side e. Malfunctioning fans e. Check for both evaporator and condenser fans Evaporator or condenser airflow Check for air restrictions, air short- circulation, grille directions g. Dirty Condenser g. Clean condenser h.
  • Page 14 c. Not stopping due to air leak, high c. Check seal, door opening, ambient temperature ambient temperature temperature setting temperature setting d. Defective controller or probe d. Check for controller and probe e. Low ambient temperature e. Change defrost settings f.
  • Page 15: Installer's Instructions

    WINE~MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed the system. Proper installation is critical. Vinotemp can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer.
  • Page 16 Parts not included: Liquid line copper tubing Suction line copper tubing Liquid and suction line locations may differ from that they are CAUTION shown below, please check on the units for proper installations. To prepare rough-in, leave minimum 4” clearances for electrical NOTE wiring and refrigeration piping.
  • Page 17 Fig. 3 Temperature Controller (4.5”L X 4.5”W X 3.75H) Fig. 4 WM-25~45SFCO Evaporator Unit - 16 -...
  • Page 18 Fig. 5 WM-250~450SCUR Condensing Unit Fig. 6 WM-Liquid Filter Fig. 7 WM-Liquid Indicator 2. Temperature Controller and Air Probe Location 1) The temperature controller can be mounted either inside or outside the wine cellar, but the air probe must be located inside. 2) The air probe shall be located in the wine cellar 5 ft above the floor or the air return area, but it shall not be located in the air supply area or other areas where air is not circulated.
  • Page 19 2) Air supply shall be unobstructed minimum 12”; air return shall be unobstructed minimum 6”. 3) There is a gravity drain system, so the unit shall be installed level or with a slight slope downward the drain connection and the drain line shall be installed slope down toward the drain.
  • Page 20 WM-4500SSO WM-4500SSO-LA <= 75 FT 1/4" OD 1/2” OD 1/2” MPT R134a / 26 OZ 1) The piping starts from  condensing unit’s receiver discharge valve  liquid filter  liquid indicator  liquid line  to evaporator unit’s liquid line connection (assembled with solenoid valve and expansion valve) ...
  • Page 21 BACK POSITION FRONT POSITION MIDDLE POSITION Fig. 9 Base Valve Operation Back Position: Normal operation, manifold port is closed. Front Position: Storage operation, liquid or suction line connection is closed. Middle Position: Installation operation, all ports are open. The recommended initial charges are used for reference only, always use the superheat, subcooling and pressure readings to charge refrigerant properly.
  • Page 22 Fig. 10 Fixed Pressure Control The adjustable pressure control (if applicable for pump-down) Suction pressure setting: Cut out=5 psig; Cut in=25 psig; Differential=20 psig Head pressure setting: Cut out=230 psig; Cut in=150 psig; Differential=80 psig It is necessary to adjust the setting in the field to reach the correct cycle time. A.
  • Page 23 III. Low ambient condition kit (if applicable) The crankcase heater The crankcase heater is installed at the bottom of the compressor and shall be turned on all the time. The heater is self-regulated. The condenser fan control The condenser fan control is installed at the high side. It closes on rise of pressure.
  • Page 24 8) If the superheat is low, then decrease the evaporator suction pressure by turning the hex nut (5/16”) counter-clockwise. Fig. 13 Expansion Valve 9) Turn both discharge and suction valves in the back positions. 10) Disconnect the manifold. 9. Pressure, Superheat and Subcooling Readings To read properly, the service valves must be in the middle CAUTION positions.
  • Page 25 8) Low suction pressure and low to normal 8) Liquid line restricted after head pressure receiver, solenoid valve High superheat and high subcooling restricted 9) Low suction pressure head 9) Suction line restricted pressure Normal high superheat subcooling 10) Low suction pressure low head 10) Air restricted at evaporator,...
  • Page 26: Electrical Wirings

    Electrical Wiring Diagrams Hidden lines are the field wirings Use minimum 14 gauge wires for power lines. CAUTION If equipped with low ambient condition kit, use low ambient temperature wiring diagrams. A safety switch is always recommended for the condensing unit. Fig.
  • Page 27 Fig. 15 WM-2500~4500SSO-LA Electrical Wiring Diagram - 26 -...
  • Page 28: Warranty

    BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
  • Page 29 VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.