Test & Debug Flow - Zenith DVB611 Service Manual

Hide thumbs Also See for DVB611:
Table of Contents

Advertisement

3. Test & debug flow
TEST
Check the AC Voltage
Power PCBA(110V or 220V)
Switch on the Power PCBA
Is the DC Voltage outputs OK?
(5V, 3.3V, 12V, 5.6V MOTOR)
Make sure the main PCBA don't short on
VCCs and switch it on.
Is 3.3V outputs normal on main PCBA?
Is 1.8V Voltage normal for Zoran IC
Connect to PC RS232 Cable and update
the FLASH memory code.
Update FLASH successfully?
A
YES
YES
YES
YES
YES
YES
YES
YES
NO
Replace power PCBA or AC transformer.
NO
Repair or Replace Power PCBA
NO
Check the regulators or related diodes.
NO
1. Check Q203.
3. Check IC102
1. Check 27MHz system clock.
NO
2. Check system reset circuit.
3. Check FLASH R/W enable signal
PRD,RWR.
4. Check RS232 SIGNALS.
5. Check FLASH Memory related circuit.
3-4
2. Check D201.

Advertisement