11. Safety devices

Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Thermal protection
protection
Terminal protection
program
(Discharge temp.)
Compressor
Thermal protection
protection
program
(Outdoor temp.)
(Only in COOL or DRY
mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 60 -
Model
AOYG09KMCDN AOYG12KMCDN AOYG14KMCDN
250 V, 25 A
250 V, 5 A
103±18 °C
Fan motor stop
95±18 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
-15 °C
Compressor stop
-10 °C
Compressor restart
125±10 °C
Fan motor stop
120±10 °C
Fan motor restart