Capacity Compensation Rate For Pipe Length And Height Difference; Model: Aoyg09Kmcdn - Fujitsu ASYG12KMCDN Design & Technical Manual

Wall mounted type
Table of Contents

Advertisement

6. Capacity compensation rate for pipe length and height
difference
Indoor unit is higher than outdoor unit
Indoor unit
Connection pipe

6-1. Model: AOYG09KMCDN

NOTE: Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
HEATING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
6-1. Model: AOYG09KMCDN
Height difference H
1
*
H
Outdoor unit
5
15
10
7.5
5
0.992
0
1.000
-5
1.000
-7.5
-10
-15
5
15
10
7.5
5
1.000
0
1.000
-5
0.995
-7.5
-10
-15
- 53 -
Indoor unit is lower than outdoor unit
Outdoor unit
H
Indoor unit
Connection pipe
Pipe length (m)
7.5
10
0.951
0.972
0.955
0.975
0.959
0.983
0.967
0.983
0.967
0.983
0.967
0.967
Pipe length (m)
7.5
10
0.967
0.934
0.967
0.934
0.967
0.934
0.962
0.930
0.960
0.928
0.926

6. Capacity compensation rate for pipe length and height difference

2
*
15
20
0.904
0.879
0.919
0.879
0.923
0.893
0.925
0.897
0.933
0.901
0.933
0.908
0.933
0.908
0.933
0.908
0.933
0.908
15
20
0.869
0.863
0.869
0.863
0.869
0.863
0.869
0.863
0.869
0.863
0.864
0.859
0.862
0.856
0.860
0.854
0.852
0.846