Section 3: Installation Location

Montigo reccommends that you install the Custom
C-View Firepit in an exterior area that is not cov-
ered. This will ensure no collection of off gases.
Should you be installing the firepit in a covered
area, you must abide by the following requirements.
Acceptable Installation 1
Install Firepit under a covered area with 3 sides open
Fig 2: Covered Installation Option 1
Acceptable Installation 2
Install Firepit under a covered area with 2 sides open
Fig 3: Covered Installation Option 2

Clearances to Surrounding Construction

Clearances to the ceiling of the space and to adjacent walls with one
wall open must meet requirements shown below:
Fig 5: Clearance to Surrounds
XG0702
Installation
Installation
Acceptable Installation 3
For covered area installations where less than 2 sides
will be fully open, there must be one side open such
that there is 10 square feet of fresh air per 20,000
BTU of your unit. A carbon monoxide detector may be
required in your jurisdiction. Please refer to local code.
Fig 4: Covered Installation Option 3
Wall
Custom C-View Fireplace
Model
Y
CFPO-2
6'
CFPO-3
7'
CFPO-4
8'
CFPO-5
9'
CFPO-6
10'
CFPO-7
11'
CFPO-8
12'
CFPO-9
13'
CFPO-10
14'
CFPO-11
15'
CFPO-12
16'
CFPO-13
17'
CFPO-14
18'
CFPO-2x2
14'
Y1
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
15.5'
Page 5