Buzzer Setting - Panasonic EYFPA1C Series Operating Instructions Manual

Hide thumbs Also See for EYFPA1C Series:
Table of Contents

Advertisement

Available languages

Available languages

Cross thread reduction func­
tion
The tool runs in reverse approximately 60°
before running forward to assist in the align-
EN
EN
ment of the threads to help reduce cross
threads.
1. Set the tool to setting configuration mode.
(See page .)
. Press the D button once.
The cross thread reduction function setting
value will be displayed.
. Press the
setting to ON or OFF.
Display
R0
R1
. Press the OK button to accept the new
setting.
Rundown error detecting func­
tion
The rundown error detecting function causes
a red indicator to flash if work ends more
quickly than a set time, for example due to
retightening of a previously tightened fastener
or binding of the screw's thread.
1. Set the tool to setting configuration mode.
(See page .)
. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
. Press the
time as desired.
Operation
. Press the OK button to accept the new
setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 60°.
and
buttons to change the
Function
OFF
ON
and
buttons to change the
Display
Seconds
0
 seconds
1
0.1 seconds
0
OFF
Maintenance interval alarm
function
The maintenance interval alarm function locks
the tool so that it can no longer be operated
once a set number of tightening operations
has been performed. This function is conve-
nient when regularly inspecting tool perfor-
mance, for example.
1. Set the tool to setting configuration mode.
(See page .)
. Press the C button twice.
The setting value will be displayed.
. Press the
desired value.
Operation
. Press the OK button to accept the new
setting.
NOTE:
When the remaining number of tighten-
ing operations is 10,000 or less, the
display will alternate between "Setting"
and "1." When the remaining number
of tightening operations reaches 0, the
value "0" will flash on the display.
To delay the inspection while retaining
the current tightening operation count
value, select a new setting value that is
greater than the current setting value.
To reset the count to 0, initialize the tool
(see page 7).
The maximum tightening operation
count value is 990,000. Operations in
excess of 990,000 will not be counted.

Buzzer setting

You can select from three buzzer modes.
1. Set the tool to setting configuration mode.
(See page .)
. Press the A button once.
The current setting value will be displayed.
. Press the
desired value.
- 6 -
and
buttons to set the
Number of tightening
Display
operations
99
990,000
1
10,000
0
OFF
and
buttons to set the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eyfpa1jEyfna1c

Table of Contents