3-2-10. Battery Alarm Signal Check

Equipment and Tools
DC power supply
DC output voltage:+1.5± 0.1 Vdc
DC current meter
Frequency Counter
Spectrum analyzer
Modulation analyzer
RF adjusting connector (See page 3-2.)
1. Frequency deviation check
Connections
(For connecting the DC supply, refer to the "Preparations"
on page 3-3.)
RF adjusting connector
SMA-BNC
conversion connector
Spectrum analyzer
Switch and control setting
S301, S302, S303, S304/ RF-87 board (A-side)
WRT-800A
S301
AU66 model
_
WRT-800A (AU)
RF-87 Board
AU-258 Board
(B side)
(A side)
TONE
Connect a jumper wire
between TONE land and
GND land by soldering.
(TONE signal OFF)
S302
S303
S304
Channel
setting
0
1
OFF
67-01
Procedure
(1) Set the spectrum analyzer as below:
CENTER FREQUENCY (fc) : 799.250 MHz
REFERENCE LEVEL
FREQUENCY SPAN
RBW (resolution band width) : 3 kHz
VBW (video band width)
ATT
(2) Decrease gradually the DC output voltage of the DC
regulated power supply and confirm that the battery
alarm signal turns on at 1 V± 0.1 V.
(3) Check that level difference between carrire frequency
(center frequency level) on spectrum analyzer and
battery alarm signal is within 29 dB ± 1 dB.
fc
32.782 kHz
: 20 dBm
: 200 kHz (20 kHz/DIV)
: 1 kHz
: 20 dB
20 dBm
29 dB ±1 dB
V : 10 dB/div