The Rating Plate (Model Nomenclature); Warranty - Bradford White Brute MagnaTech BMGV1600 Installation And Operation Instructions Manual

Hide thumbs Also See for Brute MagnaTech BMGV1600:
Table of Contents

Advertisement

1
2
3
4
5
B
M
G
SERIES
USAGE
B
M
G
H - HYDRONIC
V - VOLUME
WATER
1.3
The Rating Plate (
Consult the rating plate on the unit. The
following information describes the model
number structure.
(1-3) Model Series Designation
B = Bradford White
M G = MagnaTech
(4)
Usage
H = Hydronic
V = Volume Water
(5-8) Size
1 6 0 0 = 1,600,000 BTU/hr input
2 0 0 0 = 1,999,000 BTU/hr input
2 5 0 0 = 2,499,000 BTU/hr input
3 0 0 0 = 3,000,000 BTU/hr input
3 5 0 0 = 3,500,000 BTU/hr input
4 0 0 0 = 4,000,000 BTU/hr input
(9)
Fuel
N = Natural Gas
P = LP Gas
(10) Country Code
X = USA / CANADA
E - Export (CE - non CSA)
(11) Option Code
X = Standard Unit
J = CSD1 Version
(12) Electrical System
A - 110V,
(Single Phase)
B - 220V, (Single Phase)
C - 208V, (Three Phase)
D - 480V, (Three Phase)
E - 600V, (Three Phase)
F - 208V, (Single Phase)
(13) Additional Options
X - "H" STAMP (BMGH)
W - "HLW" STAMP (BMGV)
(14) Revision
1 = First, 2 = Second
WARNING
Electrical Shock Hazard
Electrical shock can cause severe injury, death or property
damage. Disconnect the power supply before beginning
installation or changing the wiring to prevent electrical shock or
damage to the equipment. It may be necessary to turn off more
than one power supply disconnect.
All electrical wiring is to be done in accordance with local
codes, or in the absence of local codes, with: 1) The National
Electrical Code ANSI/NFPA No. 70 - latest Edition, or 2) CSA
STD. C22.1 "Canadian Electrical Code - Part 1. " This appliance
must be electrically grounded in accordance with these codes.
Model Nomenclature
6
7
8
9
SIZE
FUEL
COUNTRY
MBTU/h
N - NATURAL
1 6 0 0
X - USA/
P - PROPANE
2 0 0 0
2 5 0 0
E - EXPORT
3 0 0 0
3 5 0 0
4 0 0 0
Model Nomenclature
10
11
OPTIONS CODE
CODE
X - STANDARD
J - CSD-1
CANADA
*
)
NOTE: Throughout the content of this manual,
the MagnaTech will be referred to as a 'unit'.
MagnaTech = unit
Altitude: Gas input rating of the MagnaTech shall be
used for elevations up to 2000 ft (600 m). The input
rating at elevations above 2000 ft (600 m) shall be
reduced at a rate of 4 percent for each 1000 ft (300 m)
above sea level before selecting the equipment size.
1.4

Warranty

Bradford White MagnaTech boilers and volume
water heaters are covered by a limited warranty. The
owner should complete the warranty registration at
http://www.BradfordWhite.com
ALL WARRANTY CLAIMS must be made by an
authorized Bradford White representative. Claims
must include the serial number and model (this
information can be found on the rating plate). All
claims must also include the installation date and
name of the installer. Shipping costs are not included
in the warranty coverage.
MagnaTech units must be installed in accordance with
the procedures detailed in this manual, or the Bradford
White warranty will be voided. The installation must
conform to the requirements of the local jurisdiction
having authority, and, in the United States, to the latest
edition of the National Fuel Gas Code, ANSI Z223.1/
NFPA54. In Canada, the installation must conform
to the latest edition of CSA B149.1 Natural Gas and
Propane Gas Installation Code, and/or local codes.
Where required by the authority having jurisdiction,
the installation of MagnaTech boilers must conform
to the Standard for Controls and Safety Devices for
Automatically Fired Boilers, ANSI/ASME CSD-1. Any
modifications to the boiler, its gas controls, or wiring
may void the warranty. If field conditions require
modifications, consult the factory representative before
initiating such modifications.
12
13
ELEC SYSTEM
ASME
A - 110V, 1Ø
X - "H" STAMP (BMGH)
B - 220V, 1Ø
W - "HLW" STAMP
(BMGV)
C - 208V, 3Ø
D - 480V, 3Ø
E - 600V, 3Ø
F - 208V, 1Ø