ELECTRICAL SEQUENCE
Refer the wiring diagram as needed.
The two ice making systems operate
independently except for the fan motor of the
remote condenser. If either one of the systems
is operating, the fan will be ON.
If the machine is switched off at the master
switch, but is otherwise ready to go, switching
the master switch to ON does the following:
• •
The bin empty light on the circuit board
goes on
• •
There is a 15 second delay
• •
If there is enough water in the reservoir, the
circuit board will allow the machine to start
up.
Start up consists of:
• •
The liquid line relay and auger motor relay
become energized, connecting power to the
liquid line solenoid coil and to the windings
of the auger motor.
• •
The liquid line solenoid opens, raising the
low side pressure.
• •
The pump down control closes.
• •
The auger motor starts, and the centrifugal
switch closes, connecting power to the
compressor contactor coil.
• •
The contactor is energized, connecting
power to: the compressor and the fan motor
relay.
• •
The fan motor and the compressor start.
• •
As ice goes past the ice level sensors, the
bin empty light will stay on, and the
machine will continue to run, unless the ice
stays between the sensors for more than
15 seconds (bin full). At that point, the bin
empty light goes out, and the machine
shuts down.
Shut Down consists of:
• •
The liquid line solenoid closes, lowering the
suction pressure.
• •
The pump down control opens.
• •
The compressor contactor opens
• •
The compressor and fan motor stop (unless
the other ice making system is on, then the
fan motor stays ON).
• •
The auger motor is run by the circuit board
for 2.5 more minutes, clearing out ice in the
evaporator, and then
• •
The auger motor relay opens, and the
auger motor stops.
If the ice level sensor is clear (bin empty) for
more than 15 seconds, the machine will start
up again.
Another purpose of the circuit board is to turn
the machine off if there is not enough water in
the machine.
• •
When the water level in the reservoir falls
below the water level sensor, the machine
will "shut down"
• •
When the water refills the reservoir, the
machine will start up again.
Separate from the circuit board:
• •
The high pressure control will stop the
machine immediately if it opens. It is
manually reset at the control and, on prior
models, at the reset switch on the circuit
board.
• •
The spout switch will stop the machine
immediately if it opens. It is a manual reset
reset switch. Prior models had an automatic
reset switch.
• •
A master switch is the manual control for
each system, but it is not a service
disconnect.