maintenance could cause this fuse to blow. If fuse replacement is
required, use ONLY a 3- -amp. fuse of identical size.

ACCESSORIES

1. Electronic Air Cleaner (EAC)
Connect an accessory Electronic Air Cleaner (if used) using
1/4- -in female quick connect terminals to the two male 1/4- -in
quick- -connect terminals on the control board marked
EAC- -1 and EAC- -2. The terminals are rated for 115 VAC,
1.0 amps maximum and are energized during blower motor
operation. (See Fig. 24.)
22
2. Humidifier (HUM)
Connect an accessory 24 VAC, 0.5 amp. maximum humidifi-
er (if used) to the 1/4- -in male quick- -connect HUM terminal
and COM- -24V screw terminal on the control board thermo-
stat strip. The HUM terminal is energized when the pressure
switch closes during a call for heat. (See Fig. 24.)
NOTE: DO NOT connect furnace control HUM terminal to
HUM (humidifier) terminal on humidity sensing thermostat, zone
controller or similar device. See humidity sensing thermostat,
zone controller, thermostat, or controller manufacturer's
instructions for proper connection.
Fig. 24 - - Furnace Control
Specifications are subject to change without notice.
A190023