Daikin FTKS09SL216 Service Manual page 47

Table of Contents

Advertisement

3. Malfunction of Protection of Jumper Cap C5
Main detection points:
● Is there jumper cap on the mainboard?
● Is the jumper cap inserted correctly and tightly?
● The jumper is broken?
● The motor is broken?
● Detection circuit of the mainboard is defined abnormal?
Malfunction diagnosis process:
Is there jumper cap on the mainboard?
Is the jumper cap inserted correctly
Replace the jumper cap with
44
Start
Yes
and tightly?
Yes
No
the same model
Is malfunction
eliminated
No
Replace the mainboard
with the same model
End
No
Assemble the jumper
cap with the same model
No
Is malfunction
eliminated
No
Insert the jumper
cap tightly
Is malfunction
eliminated
Yes
Service Manual
Appearance of the
jumper cap
Yes
Yes
Installation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents