Fujitsu PRIMERGY TX2560 M1 Operating Manual page 19

Table of Contents

Advertisement

Accessible drives / components
With most configurations the TX2560 M1 / RX2560 M1 offers 3 x 1.6" bay in the
accessible drives area located at the top of the tower server (or at the right side
of the rack) for various ODD and or backup drives.
USB connectors
Two USB 3.0 connectors on the front of the device support activities carried out
by the service technician. The maximum length of the external cable is two
meters for the USB connectors on the front.
Another four USB connectors are available on the rear of the device
(2x USB 3.0 and 2x USB 2.0).
Power supply
In its basic configuration, the server has a hot-pluggable power supply unit that
adjusts automatically to any power voltage in the range from 100 V to 240 V
(Platinum) or 200 V to 240 V (Titanium). As an option, the power supply can be
expanded with an extra power supply unit to create a redundant power supply.
If a power supply unit fails, the redundant configuration assures continued
operation. The defective power supply unit can be replaced during operation
(for further details see the "FUJITSU Server PRIMERGY TX2560 M1 / RX2560
M1 Server Upgrade and Maintenance Manual").
®
Cool-safe
Advanced Thermal Design
®
The Cool-safe
Advanced Thermal Design option allows you to operate the
system within a wider temperature range of 5 °C to 40 °C.
This option can only be ordered from the manufacturer and is
indicated by the logo on the identification rating plate.
V
CAUTION
In a system that has the Cool-safe® Advanced Thermal Design Option,
only components that support the higher operating range my be installed.
Further information on this is available in the configurator.
TX2560 M1 / RX2560 M1
Operating Manual