Graphic FX-50DU-TK(S)-C Units
3.2
FX-50DU-TK(S)-C Dimensions
Dimensions: mm (inches)
66 (2.60)
120
(4.72)
about 110
3.3
Environment Specification
Table: 3.2
Operating temperature
Storage temperature
Humidity: No condensation
Vibration resistance: 2hrs in each of 3 axis
Shock resistance: 3 times in 3 directions
Noise immunity: tested by noise simulator
Dielectric withstand voltage tested between
External I/O pins, power terminals and ground
Insulation resistance: tested between
External I/O pins, power terminals and ground
Ground: not required where impossible
Operating ambience: to be free of corrosive gases.,
Dust should be minimal.
5.5
(0.22)
160 (6.30)
170 (6.69)
SPECIFICATION.
0 to 40 °C 32 to 104 °F
-20 to 60 °C -4 to 140 °F
35 to 85% R.H.
JIS0911: 10 to 55Hz, 0.5G
JIS0912: 10G
1000 Vpp, 1µs at 30 to 100Hz
500V AC for over 1min
500V DC at more than 5MΩ
Class 3 (100Ω)