8.7.5 Execute the SYSTEM MONITOR - UTILITIES screen to view two ID fields:
The top left field on the UTILITIES screen selects which RTU is active when polling
inputs or setting outputs. This field is the only field used in Example 6 configuration.
Set this ID to 1, then execute the SINGLE POLL command. The current input status
of RTU ID 1 displays on the screen.
Change the ID to 2, then execute the SINGLE POLL command. The current input
status of RTU ID 2 displays on the screen.
Execute the ST ART POLL command to cause continuous polling at 5-second
intervals. (If RTU ID 1 Inputs are changed, the changes are reflected in screen
updates.)
Execute STOP POLL command to stop polling.
NOTE:
www.TwoWayRadioEquipment.com | (800) 878-7829 | Sales@TwoWayRadioEquipment.com
The lower left ID field is used to select which RTU is active when a
transmitter test is requested - not needed for Example 6 configuration.
EXAMPLE 6
DATAFLOW RTU
(continued!
( B-23)