Safety Devices - Fujitsu General ASHG07KMCC Design & Technical Manual

Wall mounted type
Hide thumbs Also See for General ASHG07KMCC:
Table of Contents

Advertisement

11. Safety devices

Type of
protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Thermal protection
protection
Terminal protection
Compressor
program
protection
(Discharge temp.)
Type of
protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Thermal protection
protection
Terminal protection
Compressor
program
protection
(Discharge temp.)
Protection form
Activate
Reset
Activate
Reset
Protection form
Activate
Reset
Activate
Reset
AOHG07KMCC
250 V, 20 A
250 V, 5 A
100±15 °C
Fan motor stop
95±10 °C
Fan motor restart
Compressor stop
After 7 minutes
Compressor restart
AOHG12KMCC
250 V, 20 A
250 V, 5 A
100±15 °C
Fan motor stop
95±10 °C
Fan motor restart
Compressor stop
After 7 minutes
Compressor restart
- 58 -
Model
AOHG09KMCC
110 °C
Model
AOHG14KMCC
110 °C
11. Safety devices

Advertisement

Table of Contents
loading

Table of Contents