Model 3350 - QSC III Series Technical & Service Manual

Table of Contents

Advertisement

OUTPUT POWER (per channel)
Continuous Average Output Power both channels
driven:
8 ohms,
20 Hz-20 kHz 0.1% THD
1 kHz
4 ohms,
20 Hz-20 kHz 0.1% THD
1 kHz
2 ohms,
1 kHz
Bridged Mono operation:
16 ohms,
20 Hz-20 kHz 0.1% THD
1 kHz
8 ohms,
20 Hz-20 kHz 0.1% THD
1 kHz
4 ohms,
1 kHz
Distortion:
THD – 20 Hz-20 kHz from 250 milliwatts to rated
power shall be less than 0.1%, 0.015% typical. SMPTE-IMD less
than 0.020% 250 milliwatts to rated power.
Frequency Response:
Damping Factor:
Dynamic Headroom:
Noise:
Sensitivity:
Input Impedance:
Controls:
Front – Flush detented gain control, recessed
AC switch and AC circuit breaker for each
channel.
Rear – Mono-bridging and accessory module
switches.
Indicators:
Bi-color LED indicating DC power –
OK/Protect mode, LED clip indicator, -30 dB
and -6 dB signal level indicators, flashing over-
temp indicators.
Connectors:
XLR, ¼" (ring, tip, sleeve) and 3 terminal
barrier strip inputs wired in parallel, 2-terminal
barrier strip and 5-way binding post outputs
wired in parallel, octal input sockets provided
for input transformers or active accessories,
ground lift terminal block.
200 W
1% THD
260 W
300 W
1% THD
420 W
1% THD
450 W
400 W
1% THD
520 W
600 W
1% THD
840 W
1% THD
900 W
20 Hz-10 kHz ± 0.1 dB
8 Hz-300 kHz +0/-3 dB
Greater than 200
3.0 dB at 4 ohms
-100 dB 20 Hz-20 kHz
1 V RMS for rated power (8 Ω)
20 kΩ balanced or unbalanced

Model 3350

Cooling:
Amplifier Protection:
Load Protection:
Output Circuit Type:
Output Devices (total):
Power Supply:
Power Requirements:
Dimensions:
Weight:
Passive cooling combined with high efficiency
output stage for reduced operating
temperatures. Unique circuit configuration
allows direct metal mounting of output devices
for reduced thermal stress from short-term
peaks.
Indefinite short circuit*, open circuit,
over-temp, ultrasonic and RF protection.
Stable into reactive and mismatched loads.
Inputs protected from overload. All protection
completely independent on each channel.
*
Output Averaging short circuit protection
(U.S. Pat. 4,321.554)
Individual channel Load Grounding
output relays provide DC Fault, 3 second
delayed turn on (transient protection), and
excessive low frequency protection, Instant
turn-off, pop suppression and power interrupt
protection is also provided.
Full complementary two-level high
efficiency.
16
Two completely separate power supplies
including AC switches and AC circuit breakers;
only AC cord is common.
120, 220, or 240 Volts, 50 Hz-60 Hz,
8 A (each channel)
Faceplate
19" × 3.5"
Depth (behind mtg,
with rear support)
17.9"
Depth (chassis)
15.9"
Shipping (lbs.)
46
Net (lbs.)
41
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3200335035003800

Table of Contents