Download Print this page
Midland LXT314 Alignment Procedure
Hide thumbs Also See for LXT314:

Advertisement

Quick Links

1. REFERENCE TEST EQUIPMENT
A. HP8921A Cell site test set or HP8920A, B Communication Test Set with Spectrum
Analyzer option.
B. Fluke 187 Digital Voltmeter
C. HP E3615A Power supply
2. TEST POINT
A. ANTENNA
B. VCO reference voltage
C. RX audio output
D. TX Mic. Input
E. Battery Vcc
F. Up Key
G. Down Key
H. Function Key
I. Monitor Key
J. PTT Key
K. CALL Key
Note. : All key can be activated when connect with ground.
3. VCO ALIGNMENT
A. Set unit to Channel 1 and connect a voltmeter to TP1 (VCO PD).
B. Press & hold PTT.
C. Extend L303 until the voltmeter reads 2.0V.
D. Cover shield-plate on VCO can and monitor the voltage on TP1. The voltage should be
1.5Vdc +/-0.2Vdc. If the voltage is not 2.0Vdc +/-0.2Vdc, realign L303 until meet to
requirement.
E. Release PTT button so units is in receiving mode and monitor the voltage on TP1. The
voltage should be in the range 2.0Vds +/-0.5V
F. Set unit to channel 14.
6. Press & hold the PTT switch and observe the voltage on TP4. The voltage should be 2 –
3,5 Vdc.
7. Release PTT and observe the voltage on TP4. The voltage should read between 2.0 - 3.5
Vdc.
Note : VCO shield-can should be soldered after VCO alignment is finished.
4. TRANSMITTER FREQUENCY ALIGNMENT
A. Press & hold the PTT button.
B. Align CT201 trimmer capacitor such that the output frequency is equal to the channel
frequency with a maximum error of +/- 200 Hz. CT201 is located on the left side of
20.95MHz X-tal.
LXT314
ALIGNMENT PROCEDURE
: Test point is not prepared. Use antenna contact with
ANTENNA_GND_T(antenna ground).
: Test point 1 is prepared.
: Test point SPKOUT is prepared or use ear-jack(3.5mm).
: Test point MICIN is prepared or use ear-jack(2.5mm) with 10uF
coupling capacitor.
: Test point is not prepared. Please use mechanical contact.
: Test point UP is prepared.
: Test point DW is prepared.
: Test point Menu is prepared.
: Test point SCAN is prepared.
: Test point PTT is prepared.
: Test point CALL is prepared.
Page 1

Advertisement

loading

Summary of Contents for Midland LXT314

  • Page 1 LXT314 ALIGNMENT PROCEDURE 1. REFERENCE TEST EQUIPMENT A. HP8921A Cell site test set or HP8920A, B Communication Test Set with Spectrum Analyzer option. B. Fluke 187 Digital Voltmeter C. HP E3615A Power supply 2. TEST POINT A. ANTENNA : Test point is not prepared. Use antenna contact with ANTENNA_GND_T(antenna ground).
  • Page 2 LXT314 ALIGNMENT PROCEDURE 5. TRANSMITTER OUTPUT POWER CONFIRMATION A. Set unit to channel 1 and power Hi mode. B. Press & hold the PTT button. C. Transmit power should normally be between 0.9W to 1.5W. D. Set unit to channel 14.
  • Page 3 LXT314 ALIGNMENT PROCEDURE Channel Freq. MHz Channel Freq. MHz 462.5625 467.6625 462.5875 467.6875 462.6125 467.7125 462.6375 462.5500 462.6625 462.5750 462.6875 462.6000 462.7125 462.6250 467.5625 462.6500 467.5875 462.6750 467.6125 462.7000 467.6375 462.7250 Page 3...
  • Page 4 LXT314 LABORATORY TESTING PROCEDURES UNIT TEST - (UNIT ASSEMBLED) TEST PREPARATION 1) Install 4 “AA” alkaline batteries (observe polarity markings). Left bottom terminal is the system plus polarity Right upper terminal is the system minus polarity. 2) Press the power button.
  • Page 5 LXT314 LABORATORY TESTING PROCEDURES SPECIFIC TEST METHODS AND GUIDANCE Modulation Characteristics – (paragraph 2.1047(a) of the Rules) FOR TX AUDIO FILTER RESPONSE 1. Connect audio generator with 10uF coupling capacitor to microphone input jack. Press PTT button. 2. Connect RF output with modulation meter. (Filters of modulation meter should be set to a 50Hz to 15KHz.)