Pioneer PDR-V500 Service Manual page 53

Compact disc recorder
Table of Contents

Advertisement

6.4.2 CD-R Record Power Adjustment
Test Point
Pickup objective lens
Adjustment Point
Adjustment Value
[Procedure]
(1) Turn VR102 and VR103 completely counterclockwise to set their power output to minimum.
(2) Press the ERASE button once so that "CD-R" appears on the FL display.
If the indication is "CD" or "CD-RW," press the ERASE button repeatedly until "CD-R" is displayed on the FL display.
(3) Press the RECORD button. The LED for confirmation of LD emission will light in orange.
(4) Press the REC MUTE button. The LED for confirmation of LD emission will light in red. The LD is emitting in this status.
Adjustment of CD-R record power
(5) Turn VR102 clockwise until the adjusted value is 4.60 mW ± 0.1 mW.
Adjustment of CD-R overdrive power
(6) Turn VR103 clockwise until the adjusted value becomes adjustment value at Step 5 above + (0.1 mW ± 0.01 mW).
(7) Press the STOP button to shut off the LD.
6.4.3 CD-RW Record Power Adjustment
Test Point
Pickup objective lens
Adjustment Point
Adjustment Value
[Procedure]
(1) Turn VR104, VR105 and VR106 completely counterclockwise to set their power output to minimum.
(2) Press the ERASE button twice so that "CD-RW" appears on the FL display.
If the indication is "CD" or "CD-R," press the ERASE button repeatedly until "CD-RW" appears on the FL display.
(3) Press the RECORD button. The LED for confirmation of LD emission will light in orange.
(4) Press the REC MUTE button. The LED for confirmation of LD emission will light in red. The LD is emitting in this status.
(5) Turn VR104 clockwise until the adjusted value is 0.40 mW ± 0.05 mW.
Adjustment of CD-RW record power
(6) Turn VR106 clockwise until the adjusted value is 2.40 mW ± 0.1 mW.
Adjustment of CD-RW erase power
(7) Turn VR105 clockwise until the adjusted value is 5.90 mW ± 0.1 mW.
(8) Press the STOP button to shut off the LD.
VR102 (R REC. PW1), VR103 (R REC. PW2)
VR102 : 4.60 mW ± 0.1 mW
VR103 : Addition of 0.1 mW ± 0.01 mW to the adjustment value of VR102
VR104 (RW REC. PW0), VR106 (RW REC. PW2), VR105 (RW REC. PW1)
VR104 : 0.40 mW ± 0.05 mW
VR106 : 2.40 mW ± 0.1 mW
VR105 : 5.90 mW ± 0.1 mW
PDR-555RW
51