Gas Supply; Location & Special Precautions - COZY VC201B-D Installation And Operating Instructions Manual

Gas-fired vented room heater
Table of Contents

Advertisement

GAS SUPPLY

This vented room heater must be connected to a gas supply
capable of supplying the full rated capacity. Provide a 1/
8 inch N.P.T. plugged tapping, accessible for test gauge
connection, immediately upstream of the gas supply
connection to the appliance. The minimum inlet pressure
in the gas supply pipe should be 4.5" w.c. for Natural Gas
and 11.0" w.c. for Propane Gas, "for purpose of input
adjustment". The maximum inlet pressure in the gas supply
pipe must never exceed 14" w.c. for either Natural or
Propane Gas. The gas supply piping should be sized in
accordance with ANSI Z223.1 National Fuel Gas Code.
The normal manifold pressure should be 3.5" w.c. for
Natural Gas and 10.0" w.c. for Propane Gas.
If the outlet pressure of the gas valve must be adjusted,
this must be done by a qualified service technician using
proper tools and instruments.
Check all connections with soapy water for possible gas
leaks. Never use a match, candle or other ignition source.
It is recommended that pipe compound which is resistant
to the action of liquefied petroleum gases be used. Do
not use Teflon tape or Teflon impregnated compound.
To heater gas control valve
Manual cut-off valve
1/8" NPT
Pressure Tap
Drip
Leg
GAS SUPPLY
The appliance and its individual shutoff valve must
be disconnected from the gas supply piping during
any pressure testing of that system at test pressure
in excess of ½ psig.
The appliance must be isolated from the gas supply
piping by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ psig.
Due to high temperatures the appliance should be
located out of traffic and away from furniture and
draperies.
Children and adults should be alerted to the hazards
of high surface temperature and should stay away
to avoid burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable material should not be
placed on or near the appliance.
Any safety screen, guard, or casing top removed
for servicing a room heater must be replaced prior
to operating the appliance.
Do not use this heater if any part has been under
water. Immediately call a qualified service technician
to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
For purpose of identifying the sides of the heater.
When you are facing the front of the heater the right
Gas
side has the access door and the left side is solid.
Supply
Line
If heater is installed in a residential garage, all burners
and pilot must be above 18". Locate or protect
heater so it cannot be damaged by a moving vehicle.
Page 5
GAS SUPPLY - Cont'd.
LOCATION AND SPECIAL
PRECAUTIONS

Hide quick links: