Available languages

Quick Links

Operating Instructions
Air Conditioner
Model No.
Indoor Unit
CS-YZ18UKH-8
ACXF55-17110_YA0518-0.indb 1
ACXF55-17110_YA0518-0.indb 1
Outdoor Unit
CU-YZ18UKH-8
Hướng dẫn sử dụng
Máy điều hòa không khí
Trước khi bật thiết bị, vui lòng đọc kỹ hướng dẫn sử dụng này
và giữ lại để tham khảo cho những lần sau.
Bản hướng dẫn lắp đặt đi kèm phải được cất giữ và chuẩn bi
sẵn sàng bởi người lắp đặt trước khi lắp đặt.
Điều khiển từ xa được đóng gói cùng với dàn lạnh và được gỡ
bỏ bởi người lắp đặt trước khi lắp đặt.
Operating Instructions
Air Conditioner
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read
by the installer before installation.
Remote control is packaged in the indoor unit and removed by
the installer before installation.
2-19
20-37
ACXF55-17110
3/8/2018 9:44:29 AM
3/8/2018 9:44:29 AM

Advertisement

loading

Summary of Contents for Panasonic CS-YZ18UKH-8

  • Page 1 Operating Instructions Air Conditioner Model No. Indoor Unit Outdoor Unit CS-YZ18UKH-8 CU-YZ18UKH-8 Hướng dẫn sử dụng 2-19 Máy điều hòa không khí Trước khi bật thiết bị, vui lòng đọc kỹ hướng dẫn sử dụng này và giữ lại để tham khảo cho những lần sau.
  • Page 2 Cung cấp không khí thoáng sạch với những phương thức tiết kiệm điện tối ưu. Sử dụng điều khiển trong khoảng 8 mét tính khoảng 8 từ điều khiển đến từ điều khiển đến thiết bị. thiết bị. Hướng dẫn nhanh Lắp pin Điều chỉnh đồng hồ...
  • Page 3 Cảm ơn bạn đã lựa chọn Máy điều hòa không khí Panasonic. Nội dung Hướng dẫn sử dụng an toàn ........4-11 Cách sử dụng ....12-13 Tìm hiểu thêm....14 Hướng dẫn vệ sinh máy ..15 Những vấn đề thường gặp ........
  • Page 4 Hướng dẫn sử dụng an toàn Để tránh gây thương tích cho bản thân, người khác hoặc tổn thất về tài sản, hãy làm theo những chỉ dẫn dưới đây: BÁO ĐỘNG Vận hành sai hướng dẫn sử dụng có thể gây ra hư hại với các mức độ...
  • Page 5 Nếu dây cắm nguồn bị hỏng, nó phải được thay CẢNH BÁO thế bởi nhà sản xuất, trạm bảo hành ủy quyền hoặc người có kiến thức để tránh các tai nạn. Máy cần được lắp cầu dao chống giật (ELCB) Khối trong nhà...
  • Page 6 Hướng dẫn sử dụng an toàn Phải đảm bảo rằng các chất ngoại lai (dầu, BÁO ĐỘNG nước, vân vân) không chui vào ống. Tương tự, khi bảo quản đường ống, cần bọc kín đầu hở bằng kẹp, dây buộc (bảo quản R32 giống như bảo quản R410A).
  • Page 7 1. Lắp đặt (Không gian) 2-2. Tiến hành công việc • Các sản phẩm với môi chất làm lạnh dễ cháy • Trước khi tiến hành làm việc trên các hệ nổ không được lắp đặt ở khu vực không có lỗ thống chứa môi chất làm lạnh dễ...
  • Page 8 Hướng dẫn sử dụng an toàn 2-5. Không chứa các nguồn bắt lửa 2-8. Kiểm tra các thiết bị điện • Không một cá nhân nào khi đang thực hiện • Việc sửa chữa và bảo trì các thiết bị điện phải các công việc liên quan tới hệ...
  • Page 9 4. Sửa chữa các bộ phận an toàn • Nếu phát hiện môi chất bị rò rỉ và buộc phải • Không dùng tải cảm ứng hay điện dung lâu hàn cứng, thì mọi môi chất của hệ thống phải cho hệ...
  • Page 10 Hướng dẫn sử dụng an toàn 9. Quy trình nạp nhiên liệu e) Nếu không thể tạo ra khoảng chân không, • Ngoài các bước nạp nhiên liệu thông thường, cần lặp đi lặp lại các hoạt động trên để phải tuân thủ...
  • Page 11 • Thiết bị thu hồi phải đang trong điều kiện hoạt động tốt với các chỉ dẫn liên quan tới thiết bị đang được sử dụng và phải phù hợp cho cả hoạt động thu hồi các loại môi chất dễ bắt cháy.
  • Page 12 Cách sử dụng Thay đổi hướng gió Hướng lên trên AIR SWING Đèn hiển thị Hướng nghiêng POWER TIMER • Không điều chỉnh cánh gió bằng tay. nanoe-G Để điều chỉnh tốc độ quạt AUTO FAN SPEED • Ở chế độ AUTO (TỰ ĐỘNG), tốc độ quạt sẽ được tự...
  • Page 13 Xem mục “Tìm hiểu thêm…” để biết thêm chi tiết. Để tận hưởng cảm giác thoải mái tối đa khi ngủ SLEEP (HỦY) • Chức năng này sẽ mang lại cho bạn một môi trường thoải mái khi ngủ. Nó sẽ tự động điều chỉnh nhiệt độ...
  • Page 14 Tìm hiểu thêm... Chế độ hoạt động AUTO : Trong quá trình lựa chọn chế độ hoạt động, đèn báo NGUỒN nhấp nháy. • Máy sẽ chọn chế độ hoạt động 10 phút một lần dựa trên nhiệt độ cài đặt và nhiệt độ...
  • Page 15 Hướng dẫn vệ sinh máy Để bảo đảm hoạt động tối ưu cho thiết bị, Khối trong nhà nên lau chùi và bảo dưỡng định kỳ. Máy Lá nhôm Mặt máy bị bẩn có thể gây ra sự cố và bạn có thể thấy chỉ...
  • Page 16 Những vấn đề thường gặp Những hiện tượng sau không phải do máy gặp sự cố. Hiện tượng Nguyên nhân Đèn POWER nhấp nháy trước khi máy bật. • Đây là bước khởi đầu trong quá trình chuẩn bị hoạt động khi hẹn giờ...
  • Page 17 Khi... ■Điều khiển bị mất hoặc không hoạt động 1.Nâng mặt trước. 2.Nhấn nút một lần để sử dụng ở chế độ AUTO. 3. Nhấn và giữ nút cho đến khi nghe thấy một tiếng bíp, thả tay ra để sử dụng chế...
  • Page 18 Những vấn đề thường gặp Lấy mã lỗi Nếu máy ngừng hoạt động và đèn báo TIMER (HẸN GIỜ) nhấp nháy, dùng điều khiển từ xa để lấy mã báo lỗi. Dùng vật nhọn nhấn nút Nhấn nút tới khi bạn nghe một trong 5 giây loạt tiếng bíp, sau đó...
  • Page 19 Thông tin cần lưu ý Tiếng Việt Thông tin cho người sử dụng về việc thu gom và hủy máy cũ và pin đã qua sử dụng [Thông tin về việc hủy máy ở các nước ngoài Liên minh châu Âu.] Những ký...
  • Page 20 Provides maximum comfort and clean air with optimal energy saving methods. Use remote control within 8 m from the remote from the control receiver of control receiver of the indoor unit. the indoor unit. Quick Guide Inserting the batteries Clock setting 1 Press and set the time...
  • Page 21: Table Of Contents

    Thank you for purchasing Panasonic Air Conditioner. Table of contents Safety precautions ..22-29 How to use ....30-31 To learn more....32 Cleaning instructions ..33 Troubleshooting ....34-36 Information......37 Accessories • Remote control • AAA or R03 batteries × 2 • Remote control holder •...
  • Page 22: Safety Precautions

    Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: WARNING Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: Indoor unit and outdoor unit This appliances is not intended for accessibility by the general public.
  • Page 23 If the supply cord is damaged, it must be CAUTION replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard. Indoor unit and outdoor unit It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) Do not wash the indoor unit with water, or Residual Current Device (RCD) to prevent benzine, thinner or scouring powder to avoid...
  • Page 24 Safety precautions Must always ensure that foreign matter (oil, WARNING water, etc.) does not enter the piping. Also, when storing the piping, securely seal the opening by pinching, taping, etc. (Handling of R32 is similar to R410A.) This appliance is fi lled with R32 •...
  • Page 25 1. Installation (Space) 2-2. Work • Product with fl ammable refrigerants, shall not • Prior to beginning work on systems containing be installed in an unventilated space, if that fl ammable refrigerants, safety checks are space is smaller than Amin (m²). necessary to ensure that the risk of ignition •...
  • Page 26 Safety precautions 2-5. No ignition sources 2-8. Checks to electrical devices • No person carrying out work in relation to a • Repair and maintenance to electrical refrigeration system which involves exposing components shall include initial safety checks any pipe work that contains or has contained and component inspection procedures.
  • Page 27 4. Repair to intrinsically safe components • If a leakage of refrigerant is found which • Do not apply any permanent inductive or requires brazing, all of the refrigerant shall capacitance loads to the circuit without be recovered from the system, or isolated ensuring that this will not exceed the (by means of shut off valves) in a part of the permissible voltage and current permitted for...
  • Page 28 Safety precautions 9. Charging procedures e) If a vacuum is not possible, make a manifold • In addition to conventional charging so that refrigerant can be removed from procedures, the following requirements shall various parts of the system. be followed. f) Make sure that cylinder is situated on the - Ensure that contamination of different scales before recovery takes place.
  • Page 29 • The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of fl ammable refrigerants. • In addition, a set of calibrated weighing scales shall be available and in good working order.
  • Page 30: How To Use

    How to use To adjust airfl ow direction Upper direction AIR SWING Indicator Lateral direction POWER TIMER • Do not adjust the fl ap by hand. nanoe-G To adjust fan speed AUTO FAN SPEED • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode.
  • Page 31 See "To learn more..." for details. To maximise comfort while sleeping SLEEP (CANCEL) • This operation provides you with a comfortable environment while sleeping. It will automatically adjust the sleep pattern temperature during the activation period. • The indoor unit indicator will dim when this operation is activated. This is not applicable if the indicator brightness has been manually dimmed.
  • Page 32: To Learn More

    To learn more... Operation mode AUTO : During operation mode selection the POWER indicator blinks. • Unit selects operation mode every 10 minutes according to setting temperature and room temperature. HEAT : Unit takes a while to warm up. The power indicator will blinks at initial during this operation.
  • Page 33: Cleaning Instructions

    Cleaning instructions To ensure optimal performance of the unit, Indoor unit cleaning has to be carried out at regular Aluminium fi n Front panel intervals. Dirty unit may cause malfunction and you may see nanoe-G indicator blinks or error code “H99”. Please consult authorised dealer.
  • Page 34: Troubleshooting

    Troubleshooting The following symptoms do not indicate malfunction. Symptom Cause POWER indicator blinks before the unit is • This is a preliminary step in preparation for the switched on. operation when the ON timer has been set. • When ON Timer is set, the unit may start earlier (up to 30 minutes) before the actual set time in order to achieve the desired temperature on time.
  • Page 35 When... ■The remote control is missing or a malfunction has occurred 1.Raise the front panel. 2.Press the button once to use in AUTO mode. 3. Press and hold the button until you hear 1 beep, then release to use in forced COOL mode.
  • Page 36 Troubleshooting How to retrieve error codes If the unit stops and the TIMER indicator blinks, use the remote control to retrieve the error code. Press for Press until you hear beep 5 seconds sound, then write down the error code TIMER TIMER Press for 5...
  • Page 37: Information

    Information English Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
  • Page 38 Memo ACXF55-17110_YA0518-0.indb 38 ACXF55-17110_YA0518-0.indb 38 3/8/2018 9:44:47 AM 3/8/2018 9:44:47 AM...
  • Page 39 Memo ACXF55-17110_YA0518-0.indb 39 ACXF55-17110_YA0518-0.indb 39 3/8/2018 9:44:47 AM 3/8/2018 9:44:47 AM...
  • Page 40 Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan Website: http://www.panasonic.com © Panasonic Corporation 2018 ACXF55-17110 Printed in Malaysia YA0518-0 ACXF55-17110_YA0518-0.indb 40 ACXF55-17110_YA0518-0.indb 40 3/8/2018 9:44:47 AM 3/8/2018 9:44:47 AM...

This manual is also suitable for: