Location 4 Programming The Event & Time For Output C; Locations 6 & 7 Reserved; Location 4 - GE NetworX Series Installation And Startup Manual

Remote power supply
Hide thumbs Also See for NetworX Series:
Table of Contents

Advertisement

Segment 2 selects the following partitions:
1 = "On" if the event should activate when it occurs in Partition 1.
2 = "On" if the event should activate when it occurs in Partition 2.
3 = "On" if the event should activate when it occurs in Partition 3.
4 = "On" if the event should activate when it occurs in Partition 4.
5 = "On" if the event should activate when it occurs in Partition 5.
6 = "On" if the event should activate when it occurs in Partition 6.
7 = "On" if the event should activate when it occurs in Partition 7.
8 = "On" if the event should activate when it occurs in Partition 8.

LOCATION 4

(2 segments of numerical data)
Segment 1 is used to program the particular event that will trigger Output C. Refer to Table XII:1 on page 11 for
the specific events that can be selected.
Segment 2 is used to select the amount of time an output will remain activated when an output triggers. If this
location is programmed as a zero, the output will follow the particular event.
LOCATION 5
(2 segments of feature selection data)
Segment 1 selects the following special conditions:
1 = "On" if output should time in minutes; "Off" if output times in seconds.
2 = "On" if output should latch until a code is entered; "Off" for timed.
3 = "On" if output should stop time when a code is entered.
4 = "On" for inverted output.
5 = "On" disables output during listen-in (only events 12-16).
6 = Reserved.
7 = Reserved.
8 = Reserved.
Segment 2 selects the following partitions:
1 = "On" if the event should activate when it occurs in Partition 1.
2 = "On" if the event should activate when it occurs in Partition 2.
3 = "On" if the event should activate when it occurs in Partition 3.
4 = "On" if the event should activate when it occurs in Partition 4.
5 = "On" if the event should activate when it occurs in Partition 5.
6 = "On" if the event should activate when it occurs in Partition 6.
7 = "On" if the event should activate when it occurs in Partition 7.
8 = "On" if the event should activate when it occurs in Partition 8.
LOCATIONS 6 & 7 RESERVED
NX-320E Power Supply
PROGRAMMING THE EVENT & TIME FOR OUTPUT C
PROGRAMMING SPECIAL FEATURES FOR OUTPUT C
13