Advertisement

Quick Links

INSTALLATION and OPERATION MANUAL
Self-Priming Centrifugal Pumps
IMPORTANT: Read all instructions in this manual before operating pump.
As a result of Crane Pumps & Systems, Inc., constant product improvement program, product
changes may occur. As such Crane Pumps & Systems, Inc., reserves the right to change product
without prior written notification.
PUMPS & SYSTEMS
A Crane Co. Company
420 Third Street/P.O. Box 603
Piqua, Ohio 45356-0603
Phone: (937) 778-8947
Fax: (937) 773-7157
www.cranepumps.com
Models:
G6
G9
G19
CPB RATING:
6M
8M
18M
DISCONTINUED
Parts may
NOT be available
83 West Drive, Brampton
Ontario, Canada L6T 2J6
Phone: (905) 457-6223
Fax: (905) 457-2650
Model G6
Model G9
Model G19
Form No. 096950-Rev. B

Advertisement

Table of Contents
loading

Summary of Contents for Crown G6

  • Page 1 INSTALLATION and OPERATION MANUAL Self-Priming Centrifugal Pumps Models: CPB RATING: Model G6 Model G9 Model G19 DISCONTINUED Parts may NOT be available IMPORTANT: Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur.
  • Page 2: Table Of Contents

    Other brand and product names are trademarks or registered trademarks of their respective holders. ® Crown is a registered trademark of Crane Pumps & Systems, Inc. ® Barnes is a registered trademark of Barnes Pumps, Inc. © Barnes Pumps, Inc. 1989, 1997, 1998, 2002 Alteration Rights Reserved.
  • Page 3: Warnings And Safety Precautions

    SAFETY FIRST! PLEASE READ THIS BEFORE INSTALLING OR OPERATING PUMP. GENERAL 1. Most accidents can be avoided by using COMMON SENSE. 2. Read the operation and maintenance instruction manual supplied with the pump. 3. Do not wear loose clothing that may become entangled in the impeller or other moving parts. 4.
  • Page 4: Specifications

    SECTION: A- PUMP SPECIFICATIONS - G6 & G9 SUCTION/DISCHARGE: BASE: Steel with Carrying Handle. 1-1/2" x 1-1/2", Female NPT, Flange. ENGINE MODEL: Briggs & Stratton 80232 2" x 2", Female NPT, Flange. Type: 1 Cylinder, L-Head, Air Cooled, LIQUID TEMPERATURE: 160°F (71°C) Continuous.
  • Page 5 SECTION: A- PUMP SPECIFICATIONS - G19 SUCTION/DISCHARGE: 3" x 3", Female NPT, Flange. BASE: Steel with Carrying Handle. LIQUID TEMPERATURE: 160°F (71°C) Continuous. ENGINE MODEL: Wisconsin BKND, Gasoline VOLUTE/WEARPLATE: Cast Iron ASTM A-48, Class 30. Type: 1 Cylinder, L-Head, Air Cooled, Replaceable.
  • Page 6: General Information

    SECTION B: GENERAL INFORMATION B-1) To the Purchaser: Congratulations! You are the owner of one of the finest pumps on the market today. Barnes® Pumps are products engineered and manufactured of high quality components. Over one hundred years of pump building experience along with a continuing quality assurance program combine to produce a pump which will stand up to the toughest pumping projects.
  • Page 7: Installation Recommendations

    SECTION C: INSTALLATION RECOMMENDATIONS: C-1) Location: Locate the pump as close to the source of supply as possible. Although the pump will operate on suction lifts of 25 feet, it is desirable to keep the suction lift less than 15 feet, if possible. The closer the pump can be located to the source of supply, the faster the pump will prime and a greater capacity can be pumped.
  • Page 8: Maintenance Recommendations

    In cold weather operation, the pump will not freeze as long as it is running. However, it may freeze if it is not drained while standing idle. To drain the pump, remove the drain plug at the bottom of the pump case and rotate the impeller at least once to assure removal of all the water.
  • Page 9 Under normal conditions, a grease cup full of grease will last three to four months. If a grease seal requires grease every day, and it is not leaking past the outer lip seal it indicates that the seal is wearing out. The internal pressure of the pump will often force the cup plunger out when the seal leaks badly.
  • Page 10 E-3) Impeller: These pumps have their impellers threaded on with right hand threads. The clearance between an open faced impeller and its wear surface in the volute is set at the factory at approximately .015 inches. This clearance is re adjustable by relocating the shaft at the clamping arrangement.
  • Page 11: Trouble Shooting

    TROUBLE SHOOTING CHART SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION 1. Casing not filled with water 1. Fill pump casing. Using a foot-valve will extend Little or no discharge and pump life and facilitate immediate priming. unit will not prime 2. Total head too high 2.
  • Page 12: Replacement Parts

    SECTION F: REPLACEMENT PARTS F-1 ORDERING REPLACEMENT PARTS: When ordering replacement parts, ALWAYS furnish the following information: 1. Pump serial number and date code. 2. Pump model number. 3. Pump part number. 4. Part description. 5. Item part number. 6. Quantity required. 7.
  • Page 13: Cross-Section (G6 & G9)

    Pump Models: G6 & G9 FIGURE 4...
  • Page 14: Parts List (G6 & G9)

    DESCRIPTION PART No. Washer, Lock, Split, 3/8", SS 20-14-1 Gasket, Flange MT-8650 Screw, Hex Hd., 3/8-16 x 1.25", SS 1-36-1 Flange, 1-1/2" (G6) FP-4487 Flange, 2" (G9) FP-4488 Gasket, Pump Case T-28700 Washer, Lock, Split, 5/16", SS 21-17-6 Screw, Hex Hd., 5/16-18 x 1.00", SS...
  • Page 15: Cross-Section (G19)

    Pump Models: G19 FIGURE 5...
  • Page 16: Parts List (G19)

    PARTS LIST ITEM QTY. DESCRIPTION PART No. Washer, Lock, Split, 1/2", SS 20-15-1 Screw, Hex Hd., 1/2-13 x 1.75", SS 1-71-1 Flange, 3" FP-4499 Gasket, Flange MT-8655 Gasket, Pump Case T-28699 Washer, Lock, Split, 3/8", SS 20-14-1 Screw, Hex Hd., 3/8-16 x 1.00", SS 1-34-1 Bolt, Eye, 5/8-11, Steel M-5087...
  • Page 17: Returned Goods Policy

    IMPORTANT ! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. Complete the Warranty Registration Form and returned to Crane Pumps & Systems, Inc. Warranty Service Group IMPORTANT! If you have a claim under the provision of the warranty, contact your local Crane Pumps &...
  • Page 18 Limited Warranty We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in material and workmanship under normal use and service for the following time periods, when installed and maintained in accordance with our instructions.
  • Page 19: Start-Up Report

    START-UP REPORT ENGINE DRIVEN This report is designed to insure the customer that customer service and a quality product are the number one priority with Crane Pumps & Systems, Inc. Please answer the following questions completely and as accurately as possible. Mail this form to: In U.S.A.
  • Page 20 I have received the previous information (Name of Operator) Name of Company Date: I Certify this report to be accurate (Name of Start-Up person) Employed by Date: Date and Time of Start-Up Present at Start-Up: ( ) Engineer ( ) Operator ( ) Contractor ( ) Other To be filled out by factory:...
  • Page 21 IMPORTANT ! WARRANTY REGISTRATION Your product is covered by the enclosed Warranty. Complete the Warranty Registration Form and returned to Crane Pumps & Systems, Inc. Warranty Service Group IMPORTANT! If you have a claim under the provision of the warranty, contact your local Crane Pumps &...
  • Page 22 FOLD HERE AND TAPE, DO NOT STAPLE PLACE STAMP HERE CRANE PUMPS & SYSTEMS, INC. WARRANTY SERVICE GROUP 420 THIRD STREET P.O. BOX 603 PIQUA, OHIO 45356-0603 - U.S.A.