Troubleshooting; Troubleshooting Unit; Water-To-Syrup ''Ratio'' Too Low Or Too High; Adjustment Of Dispensing Valve Syrup Flow Regulator Does Not Increase To Desired Water-To-Syrup ''Ratio - Remcor Cornelius VANGUARD 245 Installation & Service Manual

Post-mix dispenser
Table of Contents

Advertisement

IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring.
WARNING: Disconnect electrical power to the Unit to prevent personal injury before
attempting any electrical repairs to the internal components. If repairs are to be made to
one of the syrup systems, disconnect syrup supply from the system, then bleed system
pressure before proceeding. If repairs will be made to the CO
disconnect electrical power to the carbonator, shut off CO
systems pressures before proceeding.

TROUBLESHOOTING UNIT

Trouble
WATER-TO-SYRUP ''RATIO''
TOO LOW OR TOO HIGH.
ADJUSTMENT OF
DISPENSING VALVE SYRUP
FLOW REGULATOR DOES
NOT INCREASE TO DESIRED
WATER-TO-SYRUP ''RATIO''

TROUBLESHOOTING

Probable Cause
A.
Dispensing valve syrup flow
regulator not properly
adjusted.
B.
Syrup Tanks System.
CO
gas pressure to syrup
2
tanks insufficient to push syrup
out of tank.
Bag-In-Box System.
CO
gas pressure to syrup
2
pumps insufficient to operate
pumps.
A.
No syrup supply.
B.
Syrup Tanks system.
Syrup tanks CO
regulator out
2
of adjustment.
Syrup Bag-In-Box System.
Syrup pumps CO
regulator
2
out of adjustment.
C.
Dispensing valve syrup flow
control or syrup line restricted.
D.
Improper syrup Baume.
E.
Inoperative dispensing valve
syrup flow control.
F.
Tapered gasket inside tube
swivel nut connection distorted
from being overtightened
restricting syrup flow.
45
or the carbonated water system,
2
and plain water supplies, then bleed
2
Remedy
A.
Adjust Water-to-Syrup ''Ratio'' as
instructed.
B.
Adjust CO
regulator for syrup
2
tanks as instructed.
Adjust syrup pumps CO
as instructed.
A.
Replenish syrup supply.
B.
Adjust CO
2
tanks as instructed.
Adjust syrup pumps CO
as instructed.
C.
Sanitize syrup system as
instructed.
D.
Replace syrup supply.
E.
Repair dispensing valve syrup
flow control.
F.
Replace tapered gasket. Make
sure it is properly seated.
regulator
2
regulator for syrup
regulator
2
569000203

Advertisement

Table of Contents
loading

Table of Contents