Installation - Kohler REVIVAL K-14241 Installation Instructions Manual

Revival vitreous china reverse trap toilet
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

TO REMOVE EXISTING TOILET
Turn off the water supply. Flush the toilet, and use a
sponge to remove the remaining water from the tank
and bowl. Disconnect the supply shut-off valve (if
present), and remove the old tank and bowl.
Remove the old wax gasket from the closet flange with
a putty knife. Remove the old T-bolts and discard them.
NOTICE: If the new toilet is not installed immediately,
temporarily stuff a rag into the closet flange.
Install two new 5/16" diameter T-bolts into the closet
flange.
TO INSTALL SUPPLY SHUT-OFF VALVE
Install the supply shut-off valve so it is 9" (22.9cm)
above the finished floor line, and 4-1/8" (10.5cm) to the
left of the closet flange centerline.
The centerline of the supply shut-off valve outlet should
extend 3-5/8" (9.2cm) from the finished wall. Install the
supply shut-off valve with the outlet vertical.
A
1010439-2-
T-Bolts
9"
(22.9cm)
12"
(30.5cm)
2
Closet Flange
Fig. #1
Closet Flange
Fig. #2
Supply Shut-Off
Valve
4-1/8"
(10.5cm)
Closet Flange
Centerline
Fig. #3
Kohler Co., Kohler, WI U.S.A.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Revival k-3613Revival k-4445

Table of Contents