12 Technical Specifications

a. Digital Output
DIGITAL OUTPUTS
Number of output
Max continuous current
b. Bus (CAN0 and CAN1)
Analog Inputs
Number of Interfaces
Connection
Max Data rate
c. Internal Memory
Memory Type
Flash Memory
d. Power Requirements
INPUT POWER
Supply Voltage
Maximum
Operating
Current
Typical
Operating
Current
The maximum operating current consumed by the external load of digital outputs.
It is recommended to have a fast blow fuse with below rating, in series on the positive power line of 5A for 12/24V applications.
Robert Bosch Engineering and Business Solutions Private Limited | September 19, 2020
REMARKS
1 programmable High Side output shorted to the battery voltage
450 mA
REMARKS
2 CAN Interfaces
2-wires (CANH-CANL)
500 Kbps
REMARKS
eMMC, 8 GB
REMARKS
VOLTAGE
12 V
9 to 32 V (Operational)
24 V
12 V
1.5 A
24 V
1 A
12 V
750 mA (Excluding Digital Output)
24 V
400 mA (Excluding Digital Output)