SERVICE MANUAL
Not unusual during periods of
Moisture forms on
high humidity
outside of cabinet
No power at outlet.
Interior light does
Freezer is unplugged.
not work (on some
models)
Light bulb burned out.
Package holding door/lid
Door/lid wont fully
open.
close by itself
Built-in overload product.
Slow starting time
after being off
Door/lid left open.
Too frequent or too long
Excessive frost
door/lid openings.
build-up
Not unusual during periods of
high humidity

8-2. Abnormal phenomena

8-2-1. Compressor doesn't start

Com pressor
doesn' t start
Y
Whether lighting
and display system is
normal
Y
W hether the
grade of thermostat is
on 0
N
W hether
the
resistance of com pressor is
infinite or 0
N
W hether the
starting current is
about 5A
N
W hether PTC starter
resistance between running jack
and starting jack is 16-50 O
Y
Measure whether
two ends of heat protector
is through
Y
Whether the finger
of multimeter swing to 0 quickly
and then swing back slowly
N
Trouble of lighting and display system
Y
Adjust the grade according to fact
Compressor is open circuit or short
Y
Y
Inner trouble of compressor
If it is infinite or 0, then the starter is
N
N
Heat protector is out of work
N
Capacitance is out of work
Wipe surface
Replace fuse or reset the breaker
Push the plug completely into the outlet.
Replace bulb.
Store only corrects quantity of food.
Store only corrects quantity of food.
Check to see if package is holding door/lid
open.
Reduce the time of opening the door/lid
Put the freezer to suitable place
circuit
out of work.