Download Print this page
Broan SOLITAIRE ULTRA-SILENT S110FLUE Quick Start Manual
Broan SOLITAIRE ULTRA-SILENT S110FLUE Quick Start Manual

Broan SOLITAIRE ULTRA-SILENT S110FLUE Quick Start Manual

Fluorescent fan / light / night light

Advertisement

Available languages

Available languages

Quick Links

::
.com
bathroomsource
SOLITAIRE ULTRA-SILENT
FLUORESCENT FAN / LIGHT / NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
TYPICAL INSTALLATION
POWER
4" ROUND
CABLE
DAMPER/DUCT
CONNECTOR
CEILING
JOIST
GRILLE
This unit can be installed anywhere between joists using
mounting brackets provided.
INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER.
HOMEOWNER: USE AND CARE INSTRUCTIONS ON PAGE 3.
Call 1-800-667-8721 anywhere in the US and Canada -
S110FLUE
HOUSING
MOUNTING
BRACKET
FINISHED CEILING
::bathroomsource.com
Broan at
MODEL
®
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only. This
product is designed for installation in ceilings up to a 12/12
pitch. Ductwork must point up. DO NOT MOUNT THIS PROD-
UCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
The unit can be
installed in a
suspended ceiling
using wire as shown.
The unit will operate
most quietly when
located where the
shortest possible
duct run and
minimum number of
elbows will be
needed.
Plan to supply the
unit with proper line
voltage and appropriate power cable.
Follow these basic steps when installing this unit:
• Nail housing to joists.
• Attach ductwork.
• Connect power cable.
• Install blower assembly.
• Fasten grille to housing.
is a division of
www.bathroomsource.com
POWER
CABLE
kitchen::
accessories
U
N
L
I
M
I
T
E
D

Advertisement

loading

Summary of Contents for Broan SOLITAIRE ULTRA-SILENT S110FLUE

  • Page 1 This unit can be installed anywhere between joists using • Install blower assembly. mounting brackets provided. • Fasten grille to housing. INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER. HOMEOWNER: USE AND CARE INSTRUCTIONS ON PAGE 3. kitchen:: ::bathroomsource.com Broan at is a division of accessories...
  • Page 2 Check damper to make sure that it opens freely. flush with finished ceiling. Mark the top of keyhole on all four Tape all duct connections to make them secure and air tight. mounting brackets. kitchen:: ::bathroomsource.com Broan at is a division of accessories...
  • Page 3: Attach The Grille

    Use only the following 18 Watt fluorescent LINE IN lamps for the primary light and a 7 Watt maxi- mum incandescent bulb for the night light. POWER ENTERING VENTILATOR BROAN: 97010730 SYLVANIA: CF18DD827 PHILLIPS: PL-C 18W/27 ATTACH THE GRILLE GENERAL ELECTRIC: F18DBX/T4/SPX27...
  • Page 4 BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 5 • Instale el conjunto ventilador. • Asegure la rejilla a la caja. INSTALADOR: DEJE ESTE MANUAL CON EL DUENO DE LA CASA. DUENO DE LA CASA: INFORMACION DEL USO Y CUIDADO EN LA PAGINA 3. kitchen:: ::bathroomsource.com Broan at is a division of accessories...
  • Page 6 Compruebe que el registro soportes de montaje. de tiro se abre fácilmente. Cubra con cinta adhesiva todas las conexiones de ductos para hacerlas seguras y herméticas. kitchen:: ::bathroomsource.com Broan at is a division of accessories...
  • Page 7: Uso Y Cuidado

    AL VENTILADOR lámparas fluorescentes que se listan como luz primaria y una lámpara incandescente de 7 vatios para la luz de noche. SUJECCION LA REJILLA BROAN: 97010730 SYLVANIA: CF18DD827 PHILLIPS: PL-C 18W/27 GENERAL ELECTRIC: F18DBX/T4/SPX27 OSRAM: CF18DD827 NEMA: Type CFQ18W/G24d LIMPIEZA Las piezas de plástico pueden limpiarse con agua con un jabon suave.
  • Page 8: Piezas De Servicio

    PERO NO LIMITADAS A, GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR. Durante el período de un año, y a su propio criterio, Broan-NuTone reparará o reemplazará, sin costo alguno, cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso.