3.1.2

With Lowered Ceiling

APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
19" (483 mm)
C
10" (254 mm)
L
77" ( 1956 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
9" (229 mm)
B
19" (483 mm)
C
7" (178 mm)
L
77" (1956 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
16
WITH SINGLE WALL PIPE CONNECTOR
Canada
18" (457 mm)
D
28 ½" (724 mm)
E
19 ¾" (502 mm)
F
16
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
Page 14
USA
11" (279 mm)
18" (457 mm)
10" (254 mm)
77" ( 1956 mm)
USA
9" (229 mm)
19" (483 mm)
7" (178 mm)
77" (1956 mm)
FROM PIPE CONNECTOR
USA
14 ½" (368 mm)
27 ½" (699 mm)
19 ¾" (502 mm)
Ve
Ho
DISTANCES
FROM PIPE CONNECTOR
17
WITH DOUBLE WALL PIPE CONNECTOR
Canada
12 ¼" (311 mm)
D
28 ¼" (718 mm)
E
16 ½" (419 mm)
F
Installation and Operation Manual - Wood Stove
L
USA
12 ¼" (311 mm)
28 ¼" (718 mm)
16 ½" (419 mm)