J1939/11 Data Link Detail - BENDIX VORAD VS-400 Installation Manual

Hide thumbs Also See for VORAD VS-400:
Table of Contents

Advertisement

J1939/11 Data Link Detail

Shield Termination
J1939 Shield
Ref.
Body
A
DT06-3S-P032
B
DT06-3S-P032
C
DT04-3P-P007
D
DT04-3P-P006
E
DT04-3P-E008
F
DT04-3P-LE08
G
D
T
6 0
3 -
- S
0 P
6 0
G
C
38
Appendix
Recommended
Cable
Cable
Part
Manufacturer
Number
Champlain
23-00013-001
Champlain
23-00028-001
Raychem
2021D0311
Raychem
2021D0001
Raychem
2021D0301
BICC Brand-Rex
T-14945
J1939 (+)
J1939 (-)
** If an additional wire is added to the drain for insertion into the connector,
no shield terminal is used and the signal terminal quantity is 3.
If the drain wire is to be directly inserted into the connector,
then a shield terminal is used and the signal terminal quantity is 2.
Signal Terminals (QTY)
Shield Terminal (QTY)
0462-201-1631 (3) **
0462-221-1631 (1) **
0462-201-1631 (3) **
0462-221-1631 (1) **
N/A
N/A
N/A
N/A
0460-202-1631 (3) **
0460-247-1631 (1) **
0460-202-1631 (3) **
0460-247-1631 (1) **
N
A /
N
ECM #1
E
1.00 Meter
Max Length
B
B
A
A
F
A
Shield
Termination
16 Gage GXL
40.00 Meter
Max Length
J1939 (+)
(PIN "A")
Round
Color
Yes
Yellow
No
Yellow
No
Yellow
No
Yellow
Yes
Yellow
Yes
Yellow
Wedge
W3S-1939-P012
W3S-P012
N/A
N/A
W3P
W3P-1939
A /
N
A /
VS-400
VS-400
FLR
F
B
B
B
C
A
A
C
A
J1939 (-)
J1939
(PIN "B")
(PIN "C")
Color
Shield
Green
N/A
Green
N/A
Green
N/A
Green
N/A
Green
N/A
Green
N/A
Function
Through Connector
Stub Connector
"T" Receptacle
120 Ohm Termination
ECU Receptacle
Flang Receptacle
120 Ohm Termination
DIU
1.00 Meter
Max Length
A
D

Advertisement

Table of Contents
loading

Table of Contents