Disconnect power before working on pump, motor, pressure switch, or wiring.
Your Motor Terminal Board (under the motor end cover)
and Pressure Switch look like one of those shown below.
Convert to 115 Volts as shown. Do not change motor wiring
230 Volt to 115 Volt Conversion, Plug-in Type:
1.
Pull plug
straight
out from
terminal
board.
A
1.
L1
230 Volt to 115 Volt Conversion, Plug-in Type:
Move plug to change voltage.
2 3
0
1 1
5
Grounding Point
Power Supply Wires
Figure 8 – Motor wiring connections through Pressure Switch. Match motor voltage to line voltage.
Hazardous voltage. Can shock, burn,
or kill. Connect ground wire before connecting
power supply wires. Use the wire size (including
the ground wire) specified in the wiring chart. If
possible, connect the pump to a separate branch cir-
cuit with no other appliances on it.
Explosion hazard. Do not ground to
a gas supply line.
Wiring Connections
Fire hazard. Incorrect voltage can cause
a fire or seriously damage the motor and voids the war-
ranty. The supply voltage must be within ±10% of the
motor nameplate voltage.
NOTICE: Dual-voltage motors are factory wired for
230 volts. If necessary, reconnect the motor for 115
volts, as shown. Do not alter the wiring in single volt-
age motors.
Install, ground, wire, and maintain your pump in com-
pliance with the National Electrical Code (NEC) or the
Canadian Electrical Code (CEC), as applicable, and

ELECTRICAL

2.
Plug in again
Ground
with arrow
Screw
on plug
pointing to
'115 Volts'.
A
2.
L1
230 V
2 3
0
1 1
5
115 V
2 3
0
1 1
5
3781 1000
if line voltage is 230 Volts or if you have a single voltage
motor. Connect power supply as shown for your type of
switch and your supply voltage.
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
Motor wires connect here.
Power supply wires connect here.
230 Volt: Connect 2 hot wires (black and red)
here and cap the white (neutral) wire. It does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
Clamp the power cable to prevent strain
on the terminal screws.
Connect the green (or bare copper) ground wire
to the green ground screw.
with all local codes and ordinances that apply. Consult
your local building inspector for code information.
Connection Procedure
1. Connect the ground wire first as shown in Figure 8.
The ground wire must be a solid copper wire at least
as large as the power supply wires.
2. There must be a solid metal connection between the
pressure switch and the motor for motor grounding
protection. If the pressure switch is not connected
to the motor, connect the green ground screw in the
switch to the green ground screw under the motor
end cover. Use a solid copper wire at least as large
as the power supply wires.
3. Connect the ground wire to a grounded lead in a ser-
vice panel, to a metal underground water pipe, to a
metal well casing at least ten feet (3M) long, or to a
ground electrode provided by the power company
or the hydro authority.
4. Connect the power supply wires to the pressure
switch as shown in Figure 8.