Installation; Electrical Connections - Craftsman 390.2655 Owner's Manual

Professional submersible utility pump
Hide thumbs Also See for 390.2655:
Table of Contents

Advertisement

14.Protect electrical cordfromsharp objects, hot surfaces,
oil,andchemicals. Avoidkinking thecord• R eplace orre-
pairdamaged orworncords immediately.
15. D onot
touch an operating
motor.
Modem
motors
can op-
erate at high temperatures.
16. Do not handle
a pump
or pump
motor
with wet hands or
when
standing
on a wet
or damp surface,
or in water.
I Ax WARNING ] Risk of electric
shock.
If your
basement
has water
or moisture
on the floor,
do not walk
on wet
area
until
all power
has
been
turned
off.
If shut-off
box
is in basement,
call the electric
company
to shut-
off service
to the house,
or call your
local
fire depart-
ment
for
instructions.
Remove
pump
and
repair
or
replace.
Failure
to follow
this
warning
can
result
in
fatal
electrical
shock.
INSTALLATION
[_&WARNING ]Do not
use power
cord
to lift motor.
Al-
ways
use handle,
NOTICE:
Do not use this pump
in ponds
containing
plants
or fish.
ELECTRICAL
CONNECTIONS
The Pump has a 3-prong electric plug. The third prong is
used to ground the pump to prevent possible fatal shock.
The third prong should never be removed. Your electrical
outlet should be the 3-prong, polarized type v4th an inter-
nal ground.
A separate
15 amp GFCI branch
electrical
circuit
is recom-
mended.
DO NOT USE AN EXTENSION
CORD.
Testing
for Ground
For your safety, check your outlet for ground using a Circuit
Analyzer. (Figure A). A Circuit Analyzer will tell you by a pat-
tern of llghrs ffthe power, neutral, and ground wires are cor-
rectly connected
to your oudet. It can also be used to check
other outlets in your home. A Circuit Analyzer is available in
the Sears Electrical Department.
1. Pump
should
be located
and should
rest on level solid
foundation.
Do not suspend
pump
by means of discharge
pipe or power
cord. Keep pump
inlet sereen
clear.
2. Thread
outlet
pipe
into
pump
body
carefully
to avoid
stripping
or crossing
threads.
a. To install
with
3/4" garden
hose,
install
adapter
pro-
Figure
A
vided vdth pump.
b. To install with rigid pipe, use plastic pipe. Wrap thread
with
Teflon
tape or use Plasto Joint
Stik*. Screw
pipe
into pump
hand tight +1 - 1-1/2 turns.
NOTICE:
Do not try to disassemble
pump
farther
than re-
moving
inlet screen.
Any evidence
of tampering
v_ill void
warranty.
3. Power
Supply:
Pump is designed
for 115V, 60 Hz opera-
tion and requires
a circuit
of 15 amperes
or more
capac-
ity.
It is
supplied
with
a
3-wire
cord
set
with
grounding-type
plug for use in a 3-wire, grounded
outlet.
3 wire extension
cord, of at least 14 AWG (2mm z) size is
suggested,
with larger sizes for runs over 25 ft (7M). For
Figure
B
safety, pump
should
always be electrically
grounded
to a
suitable
electrical
ground such as a grounded
water pipe
or a properly
grounded
metallic
raceway,
or ground
wire
system.
Do not cut off the round
grounding
prong.
[_'WARNING_The
pump
motor
is equipped
with
automatic
resetting
thermal
protector
and
may re-
start
unexpectedly.
Protector
tripping
is indication
of motor
overloading
as a result
of operating
pump
at low
heads
(low
discharge
restriction),
exces-
sively
high
or low
voltage,
inadequate
wiring,
in-
correct
motor
connections,
or a defective
motor
or
pumtp.
UL Listed
Analyzer
Outlet"
Face Plate
/_
_
Outlet
II ±_ IIII
I /Outlet
Box
Bare Copper Wire
Face
to Cold Water Pipe
Plate Screw
653 0993
No. 4
Clamp
Clamp
Metal Water Pipe
Figure
C
Meter
6550993
"Lake Chemical Co., Chicago, IL