DISASSEMBLY PROCEDURE
9. How to remove the strainer valve
< Strainer valve >
(1) Remove the front panel.
(2) Release the band on the strainer valve.Release the
lead wire from the cable clamps. (Photos 9-1)
transportation. They do not need to be retied after this
(3)
(4) Open the drain valve to drain all water.(Photo
9-3)
(5) Remove the 2 screws (only near side) on the 2
strainer valve stay. (Photo 9-4 and 9-6)
strainer valve stay, remove the 4 screws on the strainer
valve stay, slide the strainer valve stay. (Photo 9-5)
Photo 9-3
drain valve
Photo 9-4
GCH15010
(Photo 9-2)
2 screws
strainer valve stay
2 strainer valve stays
and 2 screws
PHOTOS
cable
clamps
strainer valve
band
cable
clamp
Photo 9-2
Photo 9-5
62
Photo 9-1
pressure relief
valve cap
Photo 9-6
2 screws