Denon DCM-390 Specification page 40

Serial interface
Hide thumbs Also See for DCM-390:
Table of Contents

Advertisement

Revision1.30
Date 25.Apr.'06
2.6. 21 Power OFF
This command changes to the "Stand-by" status.
It turns off the display and stops servo rotation.
1) Command format
Byte/bit
0
1
2
3
4
5
6
7
8
2) Answers returned
Byte/bit
0
1
2
3
4
5
3) Special condition
- When "Stand-by" status, can accept "Power ON" and "Reset" command only.
- This command cannot accept "Stand-by" status.
D&M
7
6
5
Table 63. Power OFF command
7
6
5
Table 64. Power OFF answer
DCM390 Serial Interface Specification
4
3
2
STX (0x02)
Command code ('O')
Reserve (0x00)
Reserve (0x00)
Reserve (0x00)
Reserve (0x00)
ETX (0x03)
BCCH (high-level)
BCCH (low-level)
4
3
2
STX (0x02)
Reply code ('O')
Answer code (Table 3)
ETX (0x03)
BCCH (high-level)
BCCL (low-level)
40 page of 40