How To Install The Unit; Drainage (Optional) - LG W081CE SU0 Owner's Manual

Table of Contents

Advertisement

14
INSTALLATION

How to Install the Unit

1
Measure the space for installation to assure
a good fit. The air conditioner must be
installed firmly into place to prevent vibration
and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the unit.
There must be at least 50 cm (20 in.) of
cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
Foam
Awning
Cooled air
CAUTION
● The external grille must be exposed outside
for air discharge.

Drainage (Optional)

The base-pan may overflow due to high humidity.
To drain the excess water, remove the drain cap
from the base pan of the unit and secure the drain
pipe.
Fence
Heat
radiation
10~15 mm
Over 50 cm
1/4 Bubble
Level
1
Remove the rubber cap from the hole under
the base-pan.
2
Press the drain pipe into the hole by hanging
and pushing.
3
Connect the drain hose to the outlet located
on the bottom of the drain pipe. (You can
purchase the drain hose or tubing locally to
satisfy your particular needs. Drain hose is not
supplied)
CAUTION
● Take care when inserting the drain pipe.
Push away from the sharp edge to avoid
slipping and injuring yourself.
1
2

Advertisement