Dell PowerEdge 2100/180 and 2100/200 Systems Service Manual
Microprocessor/Heat Sink Assembly
heat sink
socket release
lever

Figure 4-15. Microprocessor Securing Clip Removal

To remove the microprocessor/heat sink assembly, follow these steps:
1. Remove the system board assembly.
2. Lay the system board assembly on a flat surface.
3. Remove the microprocessor securing clip from the microprocessor/heat
sink assembly.
WARNING: The microprocessor can get extremely hot during sys-
tem operations. Be sure it has had sufficient time to cool before
touching it.
Press down on the folded part of the clip with a small screwdriver to release
the clip.
4. Push outward and then upward on the release lever to rotate the lever
to its fully vertical position.
5. Lift the microprocessor/heat sink assembly out of its socket (see
Figure 4-16).
microprocessor
securing clip hooks
over tabs on socket
(front and back)
microprocessor
socket
microprocessor