Controller Options - LG LS243HLV3 Installation Manual

Single zone extended piping wall mounted
Hide thumbs Also See for LS243HLV3:
Table of Contents

Advertisement

ELECTRICAL SYSTEM INSTALLATION
Figure 84: Schematic of a Single Zone System When the Wiring is GREATER THAN 130 Feet.
Power Flow: L
N
Communication Flow: Comm
N
1(L1) (Power, L)
Power
2(L2) (Neutral, N)
G (Ground)
Supply
Diagram is an example of communication and power
cables when the wiring is GREATER THAN 130 feet.
Terminals may be labeled differently depending on the model.
Outdoor and Indoor Unit appearances may vary depending on the model.

Controller Options

Handheld Remote Controller
Single Zone Extended Piping Wall Mounted systems include a wireless handheld remote controller (Part No.
AKB74955602). Optional LG-suppled wired controllers are available. See "Functions, Controls, Options"in the
Engineering Manual, or contact an LG representative for more information.
Wireless Handheld Remote Controller features:
• Display Panel: Displays operation conditions.
• On / Off Button: Turns system operation on and off.
• Mode Button: Selects the operation mode: Cooling,
Heating, Auto, Dry (Dehumidification), or Fan.
Wired Controller Connections
Optional controllers (see the Single Zone Extended Piping Wall-Mounted Engineering Manual, or contact an
LG representative for more information) connect to the Single Zone Extended Piping Wall-Mounted indoor unit
in one of two different ways.
1. LG Wired Remote Extension Cable with Molex plug (PZCWRC1; sold separately) that connects to the
CN-REMO terminal on the indoor unit PCB.
2. Field-supplied controller cable that connects to the indoor unit
terminal block (must be at least UL2547 or UL1007, and at least
FT-6 rated if local electric and building codes require plenum
cable usage). Communication cable from indoor unit to remote
controller(s) is to be 22 AWG, 3-conductor, twisted, stranded,
unshielded. Wiring must comply with all applicable local and
national codes.
black (ground wire) terminals from the remote controller to the indoor unit terminal blocks.
Dry Contact
A Dry Contact can also be connected to the Extended Piping indoor
unit using the CN-CC connection on the indoor unit PCB. The Dry
Contact DC is shipped with a specific connector that is used to
connect to the indoor unit.
Central Controller
Additionally, Single Zone Extended Pipe systems can be connected
to a central controller if a PI-485 VNet Accessory is installed in the
outdoor unit. See the Central Controller manual for wiring specifica-
tions.
52
• Temp Up / Down Buttons: Adjusts the desired room
temperature in the different modes.
• Fan Speed Button: Sets desired fan speed.
• Reset: Initializes the handheld remote control
settings.
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
At Least Two (2) Inches
3 (Communications)
GREATER THAN 130 feet: Must Separate Communications and Ground (G) Cable from the Power
(1[L1]) and Neutral (2[L2]) Cable at Least Two (2) Inches.
Figure 86: PZCWRC1 LG Wired Remote Extension Cable.
Verify the connectors are properly inserted.
FAN
SPEED
TEMP
OPER
MODE
Figure 87: Wired Controller Connections on the Indoor Unit Terminal
Block.
Indoor Unit Terminal
RD
GR/YL
BR BL
Figure 85: AKB74955602
Wireless Handheld Remote
Controller.
Display
Screen
*
*
*
Button
Reset
C/BOX Cable (Plug type)
To Indoor Unit
CN-REMO
Terminal
Extension cable

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents