1.6 External Equipment

1.6.a Connecting a Call Flex
To support a direct connection to a call flex accessory, AquaCal
terminal blocks on the microprocessor. The microprocessor is located on the low-voltage side of the electrical
enclosure.
The call flex accessory can override a circulation pump to provide water flow to the heat
pump when the set temperature is not met. For ordering information on the accessory, see
"
Call Flex Accessory (# 0030-LEDS)

Connecting a Call Flex

DANGER
Deactivate power while routing wiring to control board.
l
Follow all National Electric Codes (NEC) and/or State and Local guidelines.
l
WARNING
This section is only for qualified installers who are familiar with the swimming pool and spa safety standards.
l
The installer must be familiar with service industry techniques.
l
NOTICE
The wire size connecting the controller must be 22-gauge (minimum), 2-conductor, low-voltage wire.
l
1. Deactivate power to heat pump.
2. Remove heat pump electrical access panel.
3. Route 22-gauge (minimum), 2-conductor, low-voltage wires
to the low voltage side of the electrical enclosure. Follow all
National Electric Codes (NEC) unless State or Local
guidelines supersede.
4. Connect the controller wires to the port labeled "Call Flex"
on the microprocessor as indicated.
5. Reattach heat pump access panel.
6. Apply power to heat pump.
7. Configure the heat pump to indicate an installed Call Flex.
See "Configure Call Flex" on the facing page.
Page - 20
" on page 68.
Failure to heed the following will result in injury or death.
Failure to heed the following may result in injury or death.
Failure to heed the following may result in damage to equipment.
®