Picture 17 - TO REMOVE VALVE ASSEMBLY
(see Technical Info IT0181)
17.3
Take off the spring
and then the tube
which goes from
coffee spout to
infuser
17.5
Take off microswitch
17.1
Take off the 2 springs
and then the
tubes
17.2
Unscrew the 2 indicated screws
using an Allen key (4)
17.4
Unscrew the indicated screw
to take off microswitch