Vermont Castings Defiant 1975-CAT-C Installation & Operating Manual page 14

Table of Contents

Advertisement

For use with either 6" or 8" flue collar/chimney connection
Stove Installed Parallel to Wall
Side
(A) 21"
Top exit with single
wall connector pipe
(521 mm)
(H) 21"
Top Exit with Double
wall
connector pipe
2
(521 mm)
(P) 21"
Rear Exit
(521 mm)
The attached rear shroud must be used in all installations. The flue collar heat shield must be used in all vertical installations.
1. The connector pipe heat shield must extend 36" (914 mm) above the flue collar.
2. Using a listed double wall oval to round connector.
3. A minimum of 67" (170 cm) from the top of the stove to the ceiling is required for all installations of the Defiant®.
14
Vermont Castings • Defiant® Model 1975-CAT-C Installation Manual_R12 • 11/21
Unprotected Surface
No Connector Heat Shield
Rear
(to back
(to rear
edge of
shroud)
cast)
(B) 15"
(C) 21"
(381 mm)
(521 mm)
(I) 15"
(J) 21"
(381 mm)
(521 mm)
(Q) 10"
(R) 16"
(254 mm)
(407 mm)
Stove Clearance
Protected Surfaces
with Connector Heat Shield
Stove in
Stove Installed Parallel to Wall
Corner
Corners
Side
(D) 5"
(E) 5"
(127 mm)
(127 mm
(K) 5"
(L) 5"
(127 mm)
(127 mm)
N/A
N/A
1
Rear
(to back
(to rear
edge of
shroud)
cast)
(F) 3"
(G) 9"
(76 mm)
(229 mm)
(127 mm)
(M) 3"
(N) 9"
(76 mm)
(229 mm)
N/A
N/A
Stove in
Corner
Corners
(D) 5"
(O) 2"
(51 mm)
N/A
8390-975