RUGGEDCOM WIN5137
Installation Guide
A single output RJ45 connector provides 10/100 Base-T data and power to the outdoor unit over a
Category 5e cable. This cable provides for the bi-directional transfer of data and signaling as well as a
power feed to the outdoor equipment.
NOTE
The Category 5e Ethernet cable is not included. Refer to
Specifications"
NOTE
The device should always be connected to a supported Power over Ethernet (PoE) injector.
The WIN5137-AC ODU CPEs are non-standard PoE devices. Do not attempt to use third-party PoE
injectors. The use of any other type of connection or application of the device and/or WIN1010 data
adapter is not permitted.
Route all power supply cords so that people cannot walk on them or place objects on or against them,
which can pinch or damage the cords.
Figure 16: Power over Ethernet Connection Schematic
1. ODU CPE
2. PoE
NOTE
Before connecting the WIN1010 data adapter to the 110/220 VAC power source, verify that all system
components are properly installed and all cable connectors are securely positioned in the appropriate
ports.
To connect power to the device, do the following:
1.
Connect a Category 5e cable between the device and the WIN1010 data adapter.
2.
Connect a Category 5e cable between the WIN1010 data adapter and a 10/100Base-T port of a switch,
router, or PC.
3.
Connect the WIN1010 data adapter to the 110/220 VAC power source using the cable.
Connecting the WIN1010 Data Adapter (AC Only)
for detailed technical specifications.
1
3
2
3. Data Adapter
4. AC Power
Section 3.5, "IDU to ODU Cable
4
5
5. Ethernet
6. Switch
7. Ethernet
Installing the Device
6
7
Chapter 2
17