Terminal Block's Terminal Fuse(Open) - Samsung AC200KNHPKH Service Manual

Hide thumbs Also See for AC200KNHPKH:
Table of Contents

Advertisement

4-3-7 Terminal Block's Terminal Fuse(Open)

Wire remote controller display
Symptom
Failure
disconnected from the terminal block and
Remove the wire connector from the PCB
and measure the resistance between two
Replace the PCB and restart the unit
Samsung Electronics
E198
Error of Terminal Block's Terminal Fuse(Open)
Fuse open
Is the wire connector
PCB?(CN140)
No
terminals
Is the resistance 0Ω ?
Yes
Yes
Connect the connector to
PCB and terminal block before
restart the unit
No
Replace the Terminal Block and
restart the unit