Download Print this page

Daikin RX15FVJU Service Manual page 10

15000/18000/24000 btu/h class
Hide thumbs Also See for RX15FVJU:

Advertisement

Removal of Outdoor Fan / Fan Motor
Step
3
Remove the nut of the
outdoor fan.
Remove the 2 lower
4
screws from the fan
motor first.
Then, remove the 2
5
upper screws.
8
Procedure
Outdoor fan
Nut size: M6
(R2694)
When reassembling, align
the
fan with the D-cut section of
the motor shaft.
(R2695)
Be sure to remove the lower
screws first. If the top
screws are removed first,
the fan motor may tilt down
or fall and cause injury
because its center of gravity
is shifted to the front.
Fan motor
(R2696)
Si00-976
Points
10 mm
(R12236)
mark of the outdoor
Removal Procedure

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Rx18fvjuRx24fvjuRxs15dvjuRxs18dvjuRxs24dvju