Table Of Contents; Gas Safety Regulations - IDEAL Concord CXi 110 Installation & Servicing Manual

Table of Contents

Advertisement

Concord CXi 110-180 (Natural gas)
CONTENTS
Air Supply. ........................................................................ 9
Boiler Assembly - exploded view. ............................... 10
Boiler Clearances. ........................................................... 6
Burner Assemblies - exploded views. .............................
CXi 110-160. .............................................................. 29
CXi 180. ..................................................................... 30
Casing Assembly. .......................................................... 14
Chimney System. ............................................................. 9
Commissioning. ............................................................. 20
Electrical Connections. ................................................. 17
Electrical Supply. ............................................................. 9
Fault Finding. ................................................................. 33
Gas Safety Regulations ................................................... 3
Gas Supply. ....................................................................... 9
Hydraulic Resistance. ...................................................... 6
Initial Lighting. ................................................................ 20
Installation. ..................................................................... 10
Mandatory Requirements. ............................................... 8
Option Kits. ....................................................................... 5
Pump. ................................................................................ 7
Servicing. ........................................................................ 27
Short List of Parts. ......................................................... 36
Static Head Requirements. ............................................. 7
System Connections. ..................................................... 13
Ventilation. ........................................................................ 9
Water Circulation. ............................................................ 5
Water Connections. ......................................................... 5
Water Treatment. .............................................................. 7
Wiring Diagrams. ........................................................... 18
Concord CXi -
Installation
B.G. Certified - P.I. No. 87/AQ/341
INTRODUCTION
CONSTRUCTION
BOILER BODY
The sectional boiler body is of cast iron and is supplied with a
sheet steel combustion chamber and integral draught diverter. The
boiler is supplied in sectioned form for site assembly.
CASING
The casing is manufactured in stove enamelled sheet steel and is
easily assembled on site.
BURNERS
The 3 burners are of stainless steel construction.
Gas Safety (Installation and Use) Regulations,
1994, amendments 1996 or rules in force.
It is the law that all gas appliances are installed and serviced by a
CORGI registered installer (identified by
the above regulations. Failure to install appliances correctly could
lead to prosecution. It is in your own interest, and that of safety, to
ensure that the law is complied with.
The Concord CXi 110-180 range of boilers has been tested and
certified by British Gas to prEN656 for use with natural gas only.
Note.
Concord CXi 110 - 180 boilers are intended for use as
COMMERCIAL BOILERS and are NOT certified for use in domestic
applications. A domestic installation is defined as an installation
where the boiler takes its combustion air from a living space or
from a room directly or indirectly connected with the living space.
It is important, therefore, that no external control devices - e.g.
flue dampers, economisers etc., are directly connected to this
appliance unless covered by these Installation and Servicing
Instructions or otherwise recommended by Caradon Plumbing
Limited in writing. If in doubt please enquire.
Any direct connection of a control device not approved by Caradon
Plumbing Limited could invalidate the British Gas Certification,
the normal appliance warranty and could also infringe the Gas
Safety Regulations. Table 1, Table 2 and the descriptive notes
which follow contain all the essential data likely to be required by
the installer.
GAS CONTROLS
The gas controls consist of a high / low arrangement with direct
burner ignition.
ELECTRICAL CONTROLS
WARNING
isolate the boiler.
The Concord CXi incorporates an advanced microprocessor-
based control system which operates all electrical functions of the
boiler, including ignition, flame detection, thermostatic control and
high/low operation. In addition, the microprocessor has onboard
servicing and commissioning instructions and a fault diagnosis
programme.
The illuminated LED display gives a continual read-out of the
boiler status and functions but, in the (unlikely) event of a fault
condition, will display the fault areas.
Destination Countries: GB and IE
.The ON/STANDBY [1/0] button does NOT electrically
) in accordance with
3