Maytag ATB1504ARQ Service Manual page 31

Amana,magic chef 15 cubic foot top mount refrigerators
Table of Contents

Advertisement

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Shunt made of 14-gauge wire
3. Test points T and H will verify the bimetal
thermostat is open or closed.
• Force motor run by shunting T to H.
• If motor doesn't run, motor is faulty. Replace ice
maker.
• If motor does run, bimetal thermostat is faulty.
Replace ice maker.
NOTE: Make sure freezer temperature is cold enough
to close the bimetal thermostat.
4. Leave jumper in for half a revolution, then touch
heater mold.
• If mold feels warm, heater works properly.
• If mold doesn't feel warm, heater is faulty.
Replace ice maker.
5. Remove jumper and water valve will energize in
last half of revolution, if mold heater has not
failed.
NOTE: Make sure freezer temperature is cold enough
to close the bimetal thermostat.
M
O
ODULE
(
NO POWER TO ICE MAKER
EJECTOR BLADES IN END
T
P
C
EST
OINTS
OMPONENT
L & H
Mold Heater
L & M
Motor
M
V
C
ODULE
OLTAGE
HECKS WITH
(
POWER TO ICE MAKER
T
P
C
EST
OINTS
OMPONENT
L & N
Module
T & H
Bimetal
L & H
Heater
L & M
Motor
N & V
Water Valve
©2003 Maytag Appliances Company
!
C
HMMETER
HECKS
;
-
-
)
OF
CYCLE POSITION
M
O
ODULE
HMS
P
OSITION
Attached
264
to support
Separated
16,100
from heater
M
T
L
ETER OR
EST
IGHT
)
L
V
0
INE
OLTAGE
VOLTS
Power OK
No Power
Open
Closed
On
Off
On
Off
On
Off
WARNING
Disassembly
NOTE: Mold & heater assembly, module assembly,
support assembly and thermostat are not
replaceable. If any of those components are
faulty, ice maker must be replaced as a unit.
1. Snap plastic cover off module.
2. Pull shut-off arm out back of support assembly.
NOTE: When reassembling unit, be sure to push shut-
off arm as far as it will go into bushing in back
of support assembly.
3. At side of mold & heater assembly, pull thermal
fuse out of its clip (See "Thermal Fuse," P . 41).
4. Remove wiring harness by depressing retainer tab
as you pull the plug out.
Mold anchor-screw
access ports (2) (Phillips)
A - 3
Module
anchor screws (3)
Shut-off
arm
Adjustment
screw
16022675

Hide quick links:

Advertisement

Table of Contents
loading