Bottom Mount Refrigerator⎯Technical Information
AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0
Due to a possibility of personal injury or property damage, always contact an authorized technician for
service or repair of this refrigerator. All safety information must be followed as provided in Service Manual
16025629.
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power
before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before
handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper
grounding and polarization.
Kw/24 hr ±0.4
Ambient °F
70°
90°
25 cu ft
1.2
2.0
Evaporator
Outlet
Ambient °F
70°
25 cu ft
-20
Schematic
December 2005
© 2005 Maytag Services
!
!
No-Load Performance, Controls in Normal Position
Percent Run Time
±10%
110°
70°
90°
110°
2.6
38
55
80
Temperature Relationship Test Chart
Evaporator
Inlet
±3°F
±3°F
90°
70°
90°
-17
-20
-17
CAUTION
WARNING
Refrigerator Center
Compartment
Average Food
Cycles/24 hr
Temperature ±3°F
±25%
70°
90°
110°
70°
90°
25
22
15
38
38
Suction Line
Average Total
±7°F
Wattage ±10%
70°
90°
70°
85
105
145
1
Freezer
Compartment
Compartment
Average Food
Temperature
Temperature
±3°F
110°
70°
90° 110°
70°
38
0
0
0
15
Suction
Pressure
Head Pressure
±2 PSIG
90°
70°
90°
70°
150
0
0
83
16026830
Ice Maker
Average
±5°F
90°
110°
15
15
± 5 PSIG
90°
135

Advertisement

Table of Contents
loading

Summary of Contents for Maytag AFI2538AE Series

  • Page 1 Average Total Head Pressure ±2 PSIG ±7°F Wattage ±10% ± 5 PSIG Outlet Inlet ±3°F ±3°F Ambient °F 70° 90° 70° 90° 70° 90° 70° 90° 70° 90° 70° 90° 25 cu ft Schematic December 2005 16026830 © 2005 Maytag Services...
  • Page 2: Component Specifications

    Clockwise RPM…………………………………… 3300 RPM 4.5 ±15% watts@12 VDC Watt……………………………………. Note: Fan blade must be fully seated on shaft to achieve proper airflow. Light switch Type…………………………………….. SPDT NO/NC Volt……………………………………… 125/250 VAC Current………………………………….. 5.0 amps 16026830 December 2005 © 2005 Maytag Services...
  • Page 3: Service Specifications

    Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated. The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes. December 2005 16026830 © 2005 Maytag Services...
  • Page 4: Defrost Operation

    CL when energized with closed defrost thermostat. Service Test – 102 Compressor / Condenser Fan • Press the Refrigerator Up eypad and Refrigerator Down eypad to toggle Compressor/Condenser fan On and Off. 16026830 December 2005 © 2005 Maytag Services...
  • Page 5 NOTE: By pushing freezer door switch you can toggle state from OP (open) to CL (closed). Service Test – 153 Disable Internal Lights • Press the Refrigerator Up eypad and Down eypad to toggle Enable (En) and Disable (dIS) internal. December 2005 16026830 © 2005 Maytag Services...
  • Page 6 Service Test – 183 Keypad Operation • Display shows a numeric or letter display indicating the last key pressed. NOTE: Refrigerator Up/Down keypads have no effect when pressed and Freezer Up/Down keypads remain operational. 16026830 December 2005 © 2005 Maytag Services...
  • Page 7 Service Test – 241 Software Revision Main Control Board • Display shows the Software revision of the Main Control Board. Service Test – 244 Software Revision Display Board • Display shows the Software revision of the Display Board. December 2005 16026830 © 2005 Maytag Services...
  • Page 8: Wiring Diagram

    16026830 16026830 December 2005 December 2005 © 2005 Maytag Services © 2005 Maytag Services...

This manual is also suitable for:

Mfi2568ae seriesAfi 2538ae*0 seriesMfi2568ae*0 series