Item
17. Display lamp
To decrease the display lamp brightness or turn it off.
brightness
1. Press and hold
adjustment
2. . Press
Remote control
• In the examples of
Operating system setting
18. Operation
mode
select table
• Do cut J804 for cooling only system
•
Do cut J805 for heating only system
•
Do cut both of J804 and J805 for return
to factory default.
Operation flow and applicable data, etc.
or
) is shown on remote control LCD then release the button.
Rise
or
Decrease
Operation display
LCD
Lamp illuminates full brightness.
Lamp illuminates 50% brightness.
Lamp illuminates 50% brightness and the
operation lamp is turned off.
All lamps are turned off.
and
for 3 seconds until brightness level (
to adjust brightness in 4 levels.
Brightness
100%
50%
50%
All turned off
, the lamp illuminates for 5 seconds before going off.
1. Purpose
Choosing the operating system as
appropriate in real condition
2.
Operation
Factory default setting prefer
"Heat pump" system. Through it is
able to cooling only system heating
only system or return to factory
default.
- 51 -
FILE NO. SVM-19004
Description
,
,